1 Door access control unit with web access
QUICK USER GUIDE
1. DESCRIPTION
WS4-4D-E is a 4-door control unit designed to operate over readers with RS-485 line.
WS4 is a completely autonomous device, operating without additional software or hard-
ware. Any device with web browser can be used for management of the WS4 system.
2. SPECIFICATIONS
• Capacity:
2500 Users
• Events:
50,000 max.
• Doors:
1 (max. 40 doors in same network)
• Readers:
2
• Door contact inputs:
1
• Push button inputs:
1
• Supply for the readers:
250 mA each max.
• Supply for the locks:
600 mA each max.
• Power supply:
15 V DC/5 A.
• Relay characteristics:
2 A/48 V AC/DC
• Processor:
ARM A5 - 528 MHz
• Memory:
64 MB RAM DDR2 133 MHz
• TCP/IP connection:
10/100/1000 Base-T – HTTP or HTTPS
• Operating temperature:
0 °C to +50 °C
• Humidity:
0% to 85% (non-condensing)
• Tamper:
Yes
• Wiegand readers connection:
Yes, via Wiegand to RS-485 converter - WS4-CNV
• Elevator feature:
Yes, 2 elevators per installation, each - 24 floors
• Interlock, Anti pass back, people counter, presence, system logs, reports in CSV
• System limits of max 40 doors and 15 WS4 (1 master + 14 slaves).
• Activate AUX OUT Relay when first person enters and last person leaves (Attendance).
• Minimum password length of 8 characters.
• The WS4 automatically creates an internal backup on USB memory stick at 23:00 only
if the configuration has been changed. A maximum of 15 backups are retained.
3. FIRST CONNECTION AND CONFIGURATION
DIP Switch pos. 1
Serial number
DIP Switch pos. 2
The WS4-1D does not have default IP address. By default is set to DHCP. There are 2
methods to connect to and configure WS4-1D-E - LAN and Standalone method.
3.1 METHOD 1
(For use in a home or business LAN network)
In this configuration, the network's DHCP server will assign an IP address to your WS4-1D-E
1. Put the DIP switch 1 in position OFF.
2. Connect a cable from your network to the ethernet connector of WS4-1D-E.
3. Open a web browser and enter http://ws4 followed dash and the serial number of
the WS4-1D-E controller
If you can not connect, it is because your network does not recognize the name of the
WS4-1D-E controller. In this case, go to our web site http://www.xprgroup.com/products/
ws4/ and download the tool called "Device Finder".
EN
The "Device Finder" will enable you to find out the IP address of the WS4-1D-E controller.
Run the "Device Finder" and you will get a list of all the WS4 controllers connected in
your network, including their IP addresses, just like the picture below.
Open a browser and type the IP of the WS4-1D-E
controller and you will be prompted to the login
page.
User Name: admin
Password: WS4 followed by Dash and the Seri-
al Number (ex. WS4-110034) just like the
image below, all in capital letters without space.
3.2 METHOD 2
(For standalone use - without LAN network)
In this configuration, the WS4-1D-E will assign an IP address to your PC. The PC must be set to obtain IP
address automatically.
1. Put the DIP switch 1 in position ON.
2. Connect a cable from your PC directly to the ethernet connector of WS4-1D-E.
3. Open a web browser and enter the following IP - 192.168.50.100, then put the login
credentials like explained above
3.3 FACTORY RESET
To do this, take the following steps:
1. Put DIP Switch 4 (Factory reset) to ON position.
2. Wait for the blinking green LED (COMM).
3. Consecutively switch the Factory reset switch (DIP 1) 3 times in the following
combination OFF - ON - OFF within 10 seconds.
4. Next, the green LED starts blinking very fast, initializes it and the factory
default is completed.
4. CHANGE PASSWORD
DIP Switch 1 allows to log into the system as an administrator if login or
password is forgotten.
1. Unplug the TCP/IP network cable (RJ45).
2. Toggle this dip switch ON for about 10 seconds, then back to OFF. The
system will then allow, for 5 minutes, to connect (from the local network
only) with the default login and password.
5. SYSTEM SETUP
5.1 ADDING READERS
Go to "Doors", select the reader(fig. 2) and then select the type of the reader in the
field "Card". (fig. 3). While off line, red LED blinks fast and buzzer beeps continuously.
Once communication is established, the red LED and the buzzer stop. Green LED
starts to blink continuously. If you want to stop the green LED, go to Settings/System
Options and select for the backlight ON or OFF (not default) (Fig. 4)
www.xprgroup.com
Fig. 1
Fig. 3
Fig. 5
To add 2 readers on 1 Door, select the reader (Fig. 2) and there, for "Type of Access"
select "Access with 2 readers" (Fig. 5). Access with 2 readers is only available for doors
1.0 and 2.0, provided that a single door is not already configured in 1.1 or 2.1 respec-
tively (Fig. 6).
5.2 ADDING USERS
Go to Users (Fig. 1), select "New" (Fig. 2) and then fill the form (Name, Category, Card
Number...) (Fig. 3).
Fig. 1
Fig. 2
5.3 ADDING SLAVE CONTROLLERS
Factory reset
One system can have up to 15 WS4 controllers (any model) and control up to 40
doors. One WS4-1D-E must be master, the others must be slaves. The master/slave
selection is made with Dip-switch 2: OFF - Master (factory setting), ON - Slave.
Go to "Doors" and click on the link "Add slave" (Fig. 1). Enter the serial number of the
WS4-1D-E to be added and click Search. If it finds it, the system directly adds this slave
into the installation and you can configure its doors (Fig. 2).
In case of error, a message is displayed in red.
Switch
Change
password
Master
Slave 1
Slave 9
DIP switch 2
DIP switch 2
DIP switch 2
OFF
ON
ON
OFF
ON
Master/
1
Slave
DIP switch 2 - ON
2
Fig. 2
Fig. 4
Fig. 6
Fig. 3
fig. 1
fig. 2
EN
1
Rev. 2.0 - 14.11.2023

Publicidad

loading

Resumen de contenidos para xpr WS4-1D-E

  • Página 1 (For standalone use - without LAN network) • Operating temperature: 0 °C to +50 °C In this configuration, the WS4-1D-E will assign an IP address to your PC. The PC must be set to obtain IP • Humidity: 0% to 85% (non-condensing) address automatically.
  • Página 2 6. Connection example of 1 door Dip Switch Autonomous Master Slave Run LED Box Tamper LED Comm Electromagnetic Lock 12 V/600 mA max Reader Diode 1N4001 Adjust the output to 14.2 V DC, using screwdriver Door contact Reader Address 1 - For doors equipped with 2 readers, one must be at address 0 and the other at address 1.
  • Página 3 Interrupteur 1. Débranchez le câble réseau TCP/IP (RJ45). Le WS4-1D-E ne comporte pas d’adresse IP par défaut. Il est réglé sur DHCP par défaut. La 2. Placez cet interrupteur DIP sur MARCHE pendant environ 10 secondes, connexion et la configuration du WS4-1D-E peuvent se faire selon deux méthodes puis replacez-le sur ARRÊT.
  • Página 4 6. Exemple de connexion - 1 porte Dip Switch Autonomous Maître Esclave Run LED Boîtier anti-sabotage LED Comm Verrou électromagnétique 12 V/600 mA max. Diode Lecteur 1N4001 Réseau Réglez la tension à 14,2 V CC à l’aide d’un tournevis. Contact de porte Lecteur Adresse 1 - Pour les portes équipées de deux lecteurs, l’un d’entre eux doit se trouver sur l’adresse 0 et l’autre sur l’adresse...
  • Página 5 • Temperatura di esercizio: da 0 °C a +50 °C • Umidità: da 0% a 85% (senza condensa) In questa configurazione, WS4-1D-E assegna un indirizzo IP al PC in uso. IL PC deve essere configurato per • Manomissione: Sì l’acquisizione automatica dell’indirizzo IP.
  • Página 6 6. Esempio di connessione - 1 porta Dip Switch Autonomous Master Slave Run LED Manomissione scatola LED Comm Blocco elettromagnetico 12 V/600 mA max Lettore Diode 1N4001 Rete Regolare l’uscita a 14,2 V CC, utilizzando un cacciavite Contatto porta Lettore Indirizzo 1 - Per le porte provviste di 2 lettori, una deve essere indirizzata su 0 e l’altra su 1.
  • Página 7 4. A continuación, el LED verde comienza a parpadear muy rápido, lo de serie de la WS4-1D-E que se vaya a agregar y haga clic en Buscar. Si la encuentra, el inicializa y se completa el valor predeterminado de fábrica.
  • Página 8 6. Ejemplo de conexión de 1 puerta Interruptores DIP Autonomous Principal Secundaria Run LED Caja de control manual LED Comm Cerradura electromagnética de 12 V/600 mA máx. Diode Lector 1N4001 Ajuste la salida a 14.2 V DC usando un destornillador Contacto de la puerta Lector Dirección 1...
  • Página 9 • Betriebsfeuchtigkeit: 0% bis 85% (nicht kondensierend) • Sabotageschutz: Bei dieser Konfiguration weist der WS4-1D-E Ihrem PC eine IP-Adresse zu. Der PC muss so eingestellt sein, dass • Verbindung mit Wiegandleser: Ja, über Wiegand-RS485-Konverter - WS4-CNV er die IP-Adresse automatisch erhält.
  • Página 10 6. Anwendungsbeispiel für zwei Tür Dip Switch Autonomous Master Slave Run LED Gehäusesabotage LED Comm Elektromagnetschloss max. 12 V/600 mA Leser Diode 1N4001 Netwerk Stellen Sie mit Hilfe eines Schraubendrehers die Ausgangspannung auf 14,2 V DC ein Türkontakt Leser Adresse 1 - Die Leser der Türen 1.0 müssen die Adresse 0 und die Leser der Türen 1.1 die Adresse 1 haben.
  • Página 11 (voor gebruik thuis of via LAN-netwerk op kantoor) • Vochtigheid: 0% tot 85% (zonder condensatie) In deze configuratie wijst WS4-1D-E een IP-adres toe aan uw pc. De pc moet worden ingesteld voor het • Sabotageschakelaar (tamper): automatisch verkrijgen van een IP-adres.
  • Página 12 6. Voorbeeld 1-deurverbinding DIP-schakelaar Autonomous Master Slave Run LED Behuizing sabotageschakelaar (tamper) LED Comm Elektromagnetisch slot 12 V/600 mA max. Diode Lezer 1N4001 Netwerk Stel de spanning in op 14,2 V DC met een schroevendraaier Deurcontact Lezer Adres 0 - Bij deuren met 2 lezers moet één lezer op adres 0 en de andere op adres 1 zijn ingesteld. Als er slechts 1 lezer is, is het aanbevolen hem op adres 0 in te stellen - LIYCY-kabel, dubbeldraad, tot 80 m Mogelijk zijn bij meer dan 80 m afsluitweerstanden (120 ohm) vereist aan beide uiteinden van de RS-...