User Manual
System
RS232, Network Firmware information and EDID functions; select an EDID mode (please see the table
above) or load an EDID file, then click on Read to confirm the choice.
RS-232 Control
Default: Baud rate 9600, 8 data bits, 1 stop bit, no parity. Baud rate can be changed via OSD menu or
software GUI. All the commands begin with SET or GET, end always with new line character
Command
GET HELP
SET RESET
GET VERSION
SET BAUDRATE w
GET BAUDRATE w
SET IP ADDRESS w
GET IP ADDRESS
SET SUBMASK w
GET SUBMASK
SET GATEWAY w
GET GATEWAY
SET NETPORT w
GET NETPORT
SET NETWORK-INFO IP PORT
SUBMASK GATEWAY
GET NETWORK-INFO
Details
Get the Commands list
Recover to default setting
Get firmware version
Return: VERSION w (w is version number)
w is 9600, 19200, 38400, 57600 or 115200
Return: BAUDRATE w
Return: BAUDRATE w
For example: SET IP ADDRESS 192.168.0.247
Return: IP ADDRESS w
Return: IP ADDRESS w
For example: SET SUBMASK 255.255.255.0
Return: SUBMASK w
Return: SUBMASK w
For example: SET GATEWAY 192.168.0.1
Return: GATEWAY w
Return: GATEWAY w
For example: SET NETPORT 2000
Return: NETPORT w
Return: NETPORT w
For Example:
SET NETWORK-INFO 192.168.0.247 2000 255.255.255.0
192.168.0.1
Return: NETWORK-INFO 192.168.0.247 2000 255.255.255.0
192.168.0.1
Return: NETWORK-INFO IP PORT SUBMASK GATEWAY
English
(CR).