Cleaning, Care & Maintenance
Switch off and disconnect from the power supply before cleaning
The doors can be removed for ease of cleaning
Clean the interior of the appliance as often as possible
Do not use abrasive cleaning agents. These can leave harmful residues
Clean the door seals with warm soapy water
Always wipe dry after cleaning.
Condensation and ice will form with frequent and prolonged opening of the doors.
Operating outside of the recommend temperature range and placing next to a heat source
will also increase the amount of ice and internal/external condensation. If external
condensation occurs wipe the surface down with a cloth.
Excessive ice will result in longer running times that will increase energy consumption and
increase the deterioration of components.
Cleaning the Condenser
Periodic cleaning of the Condenser can extend the life of the appliance, POLAR recommend that a POLAR
agent or qualified technician clean the condenser.
Troubleshooting
A qualified technician must carry out repairs if required.
Fault
The appliance is not
working
The appliance is not
cooling
The Light does not
work
Error code EE4
CG841_ML_A5_v4_20230926.indb 5
CG841_ML_A5_v4_20230926.indb 5
Probable Cause
The unit is not switched on
Plug or lead is damaged
Fuse in the plug has blown
Mains power supply fault
Coolant Leak
Fan Motor Failed
Airflow to the condenser
obstructed
Condenser is clogged
Bulb has blown
Restricted Airflow
Blocked Condenser
Solution
Check unit plugged in correctly and
switched on
Replace Plug or lead
Replace the fuse
Check mains power supply
Consult a qualified Technician
Consult a qualified Technician
Increase the gap between appliance and
obstacles/heat source
Consult a qualified Technician
Consult a qualified Technician
Increase airflow
Consult a qualified Technician