Installation
If replacing an older faucet
ensure water supply is turned
OFF before removing, then
turn faucet control valve ON to
relieve water pressure.
DO NOT use pipe dope
or thread sealant on drain
assembly, or any plastic
threaded components.
1) Insert hoses from faucet body
(H) and threaded rods (J) through
mounting gasket (K) and sink
holes.
2) Place brackets (L) onto threaded
rods (J). Secure with nuts (M).
J
1
1
M
3) Push Pop Install: Insert drain
body (L) into drain opening. From
below, Tighten locking nut (O)
with gasket (M) and washer (N)
to flange. Tighten tail nut (Y) with
washer (X) to secure tail pipe (Q).
DO NOT overtighten.
Plumbers Putty
H
J
4) Attach supply lines to shut-off
K
valves and hand tighten. Using a
wrench, finish with one-half turn.
DO NOT overtighten.
1
L
2
L
1
M
N
2
O
X
3
Q
Y
1
2
3
5) Remove aerator (I) and flush lines
free of debris. Check for leaks.
6) Adjust limit stop washer to limit
handle turn to the hot position if
desirable.
Note: Counterclockwise to lower
temperature, clockwise to increase
temperature.
I