4.3 Single Shot and Continuous Scanning Modes
When the Pro400 is first switched on, it is set to "Single Shot"
mode. In this mode the Pro400 only fires a pulse into the cable
under test when either the
Single Shot Mode: Saves on battery life and enables the
Pro400 to be disconnected from the cable while still leaving
the fault display on the screen.
To enter "Continuous Scanning" mode press down and hold the
▼button.
The icon will appear at the bottom right of the display when
continuous scanning mode is activated.
Continuous Scanning Mode: Fires the pulses into the cable
under test. In this mode the Pro400 can more easily identify
intermittent cable faults.
4.4 Gain Adjustment
To increase the gain of the return pulse, align cursor at the
beginning of the event. Press and hold
increase or decrease gain.
4.5 Tone Generator
The Pro400 may also be used as a tone generator to trace and
identify cables and wires. The user will need a conventional
inductive tone probe within the range of 810 Hz to 1110 Hz.
To select tone generator (Level 2)
buttons or ▼button is pressed.
button, press
Select
12
keys to