Descargar Imprimir esta página

ESPA evopool Silenplus 1 Manual De Instrucciones página 14

Publicidad

9. LED INDICATORS
In Silenplus pump:
The possible LED combinations and their meanings are:
0 = LED OFF
1 = LED ON
2 = LED flashing slowly
3 = LED flashing quickly
AUTO/
BACKWASH
MANUAL/
Plus
FAULT
0
0
0
1
0
1
1
0
1
1
1
1
2
0
3
3
(.. .t og e th er ...)
3
0
3
1
3
1
2
1
2
1
When moving the control of the ControlSystem:
Number of flashes
3
2
1
0
FILTRATION
Equipment status
Plus
Functions
1
Filtration Plus function in Auto mode.
0
Backwash Plus function in Auto mode.
1
Mixed Cycle function in Auto mode. Motor at 100%.
1
Filtration Plus function in Manual mode.
0
Backwash Plus function in Manual mode.
1
Mixed Cycle function in Manual mode.
"Standby" mode. The equipment has power, motor stopped.
a) Valve in intermediate positions or position 6 in Auto mode.
0
b) Stop function in Manual mode.
c) Timer OFF position.
Configuration
3
Initial configuration: standing by for link with ControlSystem
1
Filtration Plus speed setting.
0
Backwash Plus speed setting.
1
Mixed Cycle speed setting.
2
No water error. Start-up retry attempted.
1
No water error. Full shut-down.
ControlSystem status
The ControlSystem is not linked to any Silenplus.
Communication error. Call for service.
The ControlSystem works correctly.
Replace the ControlSystem battery
Errors
16
EN

Publicidad

loading

Productos relacionados para ESPA evopool Silenplus 1

Este manual también es adecuado para:

Silenplus 2Silenplus 3