English
Application
Bus standard line rectifier for Siedle
In-Home bus. For supplying and
controlling the bus user audio/video.
For new systems with max. 10 users,
one bus door station supports two
users.
AC voltage integrated, for door
release and nameplate lighting for
example.
Application
The line rectifier may only be used
exclusively to supply Siedle appli-
ances. Any other application is
deemed not in accordance with its
intended use and exonerates the
manufacturer from any liability.
Electrical voltage
• Mounting, installation and ser-
vicing work on electrical devices may
only be performed by a suitably
qualified electrician. Failure to
observe this regulation could result
in the risk of serious damage to
health or fatal injury due to electric
shocks.
• Operation at an altitude of up to
2000 m above sea level.
• Observe EN 62368-1! In a building
installation, an all-pole mains switch
with a contact opening of at least
3 mm must be provided. The device
must not be exposed to water drops
or sprayed water! Sufficient ventila-
tion must be ensured. Pay particular
attention to ensure that ventilation
slots are not covered.
• When using stranded cores as
cable material, these must be fitted
with wire end ferrules without fail.
Scope of supply
• Bus standard line rectifier
BSNG 650-0
• Programming – Plug+Play
• Programming – manual
• This product information
6
For download
• System Manual In-Home bus
Accessories
Optional plug-in facility for the bus
supply unit accessory ZBVG 650-...
Terminal assignment
L1, N
Power connection
Ta, Tb
In-Home bus
b, c
Power supply 12 V AC
Tö, Tö
Relay contact door
release
Li, Li
Relay contact light
Mounting
1 Clip the bus line rectifier onto the
top hat rail.
2 Basic circuit diagram for audio
3 Basic circuit diagram for video
Note
a) The camera branch and monitor
branch must be laid separately and
must not be located in the same
cable. This can result in disturbance
to the picture composition.
Commissioning
Installation and commissioning are
described in the system manual.
The latest issue can be found in the
download area at www.siedle.com.
4 Operating elements and
functional displays
a
LED 1 = Operational LED
LED 2 = Error LED
b
Button for programming
mode ON/OFF.
Conductor length
Conductor material J-Y(St)Y cable
with 0.8 mm diameter:
5 In-Home bus: Audio
6 In-Home bus: Video
With a core diameter of 0.6 mm,
the range is halved.
Specifications
Operating voltage:
230 V AC, +/-10 %, 50/60 Hz
Operating current: 200 mA
Output voltage: 27.5 V DC, 12 V AC
Output current: 0.5 A DC, 1 A AC
Fusing: Primary fuse 1 T 250 mA L,
secondary short circuit proof
Contact type:
2 n.o. contacts 24 V, 2 A
Protection system: IP 30
Ambient temperature:
0 °C to +40 °C
Horizontal pitch (HP): 9
Dimensions (mm) W x H x D:
162 x 89 x 60