This product is warranted against any faults in materials or manufacture for 3 years from the purchase
SPECIFIC INFORMATION
INSTRUCTIONS FOR USE – COBRA 2
Summary
This product is intended for use to protect and prevent against risks of falling from above in industry, in construction
work, in rescue and, more generally, for any application of work at a height.
performance requisites for fall factor 2 (tested in compliance with EN 355:2002 point 4.4).
Use
During user movement, the webbing [2] winds and unwinds on a reel inside the retractable device [1]. The webbing
is held constantly under tension by a re-winder spring. In the case of a fall, a mechanism locks the webbing and
[3] that reduces the braking force (<6 kN). Each
time you use the device, check the locking function by pulling hard on the webbing. Do not release the webbing
suddenly: guide it back by hand on to the re-winder reel inside the device. Check that the cable unwinds and rewinds
freely, with no obstruction. The swivel device [4] must be connected to a structural attachment point by means
of a connector EN 362 The anchor point must be in compliance with the EN795 standard and/or known to have
The end loop [5] must be connected to the fall
[6] supplied with the device.
The maximum admissible load is 100 kg. In order to evaluate the hazard level of a work situation, the Fall Factor is
is less than 1, i.e. with the operator below the attachment point, Cobra 2 is used in conformity with standard EN
360. Cobra 2 can also be used in other cases with fall factors of up to 2. In any case the use as to EN360 with the
attachment point above the user is to be preferred, in order to reduce the fall distance and hence ensure greater
safety. (
). The connector-retractable fall arrester-connector system must never exceed a length of 2 m (with
the webbing completely extended) (
).
Use as to EN 360 (fall factor 0)
The structural attachment point to which the device is connected must be above the user (fall factor 0). To avoid any
must pay particular attention, as protection in the case of a fall may not be complete (
).
Use with fall factor 2
In this type of use the structural attachment point where the device is connected can be below the user (maximum
not available the user must pay particular attention, as protection in the case of a fall may not be complete (
).
In any case we suggest you reduce to a minimum the situations with fall factor 2, by keeping the attachment point
connector having a wide opening (art. 2017) that may be connected to the tubular structure and assembled with the
). Cobra 2 is not for applications
where the webbing [2] could contact a sharp edge. Rescue equipment and trained rescue workers are required for