OWNER'S MANUAL | USING YOUR BLACKSTONE
CoNNeCT THe lPG CYlINdeR
ONLY USE A 1 LB (453 G) CYLINDER
Screw in the lPG
STEP 01
cylinder into the gas regulator,
turning the cylinder clockwise�
The regulator may make a humming
The regulator may make a humming
or whistling noise during operation.
or whistling noise during operation.
This will not affect safety or use of the
This will not affect safety or use of the
appliance.
appliance.
Insert the regulator and lPG cylinder into the gas line of the
STEP 02
appliance� Turn the collar of the regulator clockwise to secure it to
the gas line�
LPG CYLINDER SAFETY
• The lPG supply cylinder to be used must be constructed and
marked in accordance with the specifications for lP gas cylin-
ders, U�S� department of Transportation (doT) or the Standard for
Cylinders, Spheres and Tubes for the Transportation of dangerous
Goods, CAN/CSA-B339�
• only lPG cylinders marked "propane" shall be used�
• The cylinder used, if in excess of 2�2 Ib (1�00 kg) propane capacity,
must include a collar to protect the cylinder valve�
• The lPG cylinder supply system must be arranged for vapor
withdrawal�
Always keep new lPG cylinders in upright position during use, transit or
Always keep new lPG cylinders in upright position during use, transit or
storage.
storage.
ensure that the lPG cylinder is positioned below the regulator�
(If the liquid level of the propane is above the regulator, the regulator will frost.)
(If the liquid level of the propane is above the regulator, the regulator will frost.)
IF FROSTING PERSISTS AFTER BOTTLE IS ANGLED CORRECTLY:
Turn off the appliance and disconnect lPG cylinder imme-
STEP 01
diately� This indicates a problem with the lPG cylinder and it should
not be used on any product�
Return lPG cylinder to supplier�
STEP 02
08
The gas regulator is intended to be
The gas regulator is intended to be
used at an angle towards the rear of
used at an angle towards the rear of
the appliance.
the appliance.
REGULATOR SAFETY
• Use this appliance, as purchased, only with gas and regulator/valve
assembly supplied�
• do NoT cross thread the connection between your lPG cylinder
and regulator�
Cross threading can occur if you force thread a connection at an improper
Cross threading can occur if you force thread a connection at an improper
angle. This will damage the threads, lead to propane leaking, and potentially
angle. This will damage the threads, lead to propane leaking, and potentially
result in a build-up of fuel that can ignite.
result in a build-up of fuel that can ignite.
• If you can not connect the regulator, do NoT use the regulator�
Regulator must be replaced with a Blackstone approved model by a profession-
Regulator must be replaced with a Blackstone approved model by a profession-
ally licensed, authorized dealer.
ally licensed, authorized dealer.
LEAK TEST INSTRUCTIONS
Turn the control knobs to oFF�
STEP 01
Connect the lPG cylinder to the regulator� Connect the
STEP 02
regulator to the appliance�
Use a clean paintbrush
STEP 03
to brush a 10/90 mild soap and
water solution onto joint areas of
valves and regulator�
leaks are indicated by growing
leaks are indicated by growing
bubbles.
bubbles.
If growing bubbles appear, re-tighten connections�
STEP 04
If leaks cannot be stopped, DO NOT try to repair.
Regulator must be replaced with a Blackstone approved
model by a professionally licensed, authorized dealer.
DISCONNECTING THE LPG CYLINDER
1 LB (453 G)
ensure that the control knob(s) are turned to oFF�
STEP 01
once the appliance has cooled, disconnect the regulator
STEP 02
from the gas line by unscrewing the collar�
Unscrew the lPG cylinder from the regulator�
STEP 03
Place dust cap on lPG cylinder valve outlet whenever
STEP 04
cylinder is not in use�
only install the type of dust cap on cylinder valve outlet that is provided
only install the type of dust cap on cylinder valve outlet that is provided
with the cylinder valve. other types of caps or plugs may result in leakage of
with the cylinder valve. other types of caps or plugs may result in leakage of
propane.
propane.
STORING LPG CYLINDERS
• DO NOT store a spare LPG cylinder under or near this
appliance.
• DO NOT fill an LPG cylinder beyond 80% full.
If the information above is not followed exactly, a fire causing
death or serious injury may occur.
• The lPG cylinder must be disconnected when the appliance is
not in use�
• only store the appliance indoors if the lPG cylinder is disconnected
and removed from the appliance�