CONNECTING THE POWER
240AC or 208AC
60HZ
External thermostat
If you will use an external temperature control (external thermostat) to control
the heater, please follow below attention points:
1. Make sure that the heater's temperature control knob (thermostat knob) is turned
fully clockwise.
2. Connect the wire according to below wiring diagram.
240AC or 208AC
60HZ
External thermostat
Terminal station
1
2
LINE
LOAD
RED
BLACK
4
3
External thermostat
All manuals and user guides at all-guides.com
INSTALLATION
L1
L2
1
2
E
GND
L1
L2
1
2
E
GND
2500W 2500W
PCB
Selected switch
2500W 2500W
PCB
Selected switch
8
2500W
Heater's
External
thermostat
thermostat
Selection Switch
(Heater's thermostat, External thermostat)
2500W