You have received a pre-assembled adjustable welding angle and a detailed operating manual.
Please check the condition of the goods upon receipt for any damage incurred during transport, and make
sure the delivery is complete. If you have any problems, please contactthemanufacturerimmediately.
1. Follow the safety instructions. Clean the workpiece and the lower magnetic plate of the
switchable magnetic clamp.
2. Release all three clamping levers. Adjust the angle of the magnets to each other according to the desired
application. Now tighten the three levers again with ca. 5-6 Nm to fix the assemblies in place.
3. Place the magnetic clamp into the desired position or put the work piece onto the magnetic surface.
The magnetic clamp is slightly magnetized in order toassist positioning the magnet and the work piece.
4. Align the work piece and the magnet according to the desired application.
5. Turn the activation lever by 60° into the ON position until it audibly latches into place (with a slight tilting).
6. Check the secure and strong hold of the magnet and the work piece depending on application.
7. After the load has been set down completely and safely, you can deactivate the magnetic clamp.
To do this, push the activation lever at its far end upwards (1.) and move it into the OFF position (2.).
During each application, watch for any deformation of the work piece that might occur. If a small distance
(air gap) forms between the magnetic surface and the work piece, the magnetic clamp will not reach the
stated holding force and could detach itself. Please check for any air gap developing at the edges of the
TiN-coated magnetic surface if necessary (e.g. with a sheet of paper; 80g/m
14
immediately stop the application if there is any
!
excessive deformation of the work piece or if an
air gap occurs.
never exceed the dimensions and/or the
!
load-bearing capacity of the values given in
table 2 (page 16).
).
2