will turn off and the ventilation speed is set to
the minimum. Press any button to switch on
the machine and standby mode will switch off.
Information on air
quality display
The purifier has a PM2.5 sensor that detects
small particles up to 2.5 μm in size. The air pu-
rifier displays the colour that corresponds to
the concentration of particles in the ambient
air near the device.
Colour
Air quality
Blue
Yellow
Acceptable
Orange
Red
Very poor
Timer function
The air purifier has a timer function with which
you can decide on the number of hours after
which the device must stop. The air purifier has
three timer periods: 2HRS (two hours), 4HRS
(four hours) and 8HRS (eight hours).
To move from one timer speed to another, press
the timer button. The timer length indicator as
currently configured will light up on the con-
trol panel. The air purifier then switches off au-
tomatically after the number of hours defined.
To switch off the timer, press the timer button
until no light is lit above the button. The air pu-
rifier will then run with no time limit.
Changing the air filter
You must replace the three-layer filter after 4,320
hours of use. The blue "Filter Reset" LED beside
the Stop/Start button flashes after 4,320 hours
of use. To replace the filter, proceed as follows:
Turn the purifier upside down.
Unscrew the bolt under the
base followed by the base.
PM 2.5 value
in µg/m³+
Good
0-33
34-66
Poor
67-99
>100
Remove the dirty filter and insert
the new filter into the device.
Plug in the device and press the On/
Off button for 3 to 5 seconds. The
program will reset the filter usage time.
Put the base back in place and fix it using the
fastening nut.
Replacing the UV light
The UV light has a life of 20,000 hours.
Unscrew the UV light's holder:
Gently remove the cover and
unscrew the UV light.
Insert a new UV light then
put the cover back on.
Note: Do not look at the
UV light when it is lit.
Trouble shooting
The air purifier does not switch on.
The casing cover has not
been installed properly.
Make sure that the casing
cover is in the right position.
The three-layer filter has not
been installed properly.
Make sure that the three-layer
filter is the right position.
The mains adapter is not connected.
Plug the mains adapter into
a suitable power socket.
There is insufficient
throughput of air
The filters are clogged.
Clean the filters (see the chapter
on "Maintenance and Storage").
The air inlet/exhaust is blocked