regulates the living rooms to the lower set-
back temperature (2) that is set.
2.7 Preventing malfunctions
Do not cover the system control with
furniture, curtains or other objects.
If the system control is installed in the
living room, open all of the thermostatic
radiator valves in this room fully.
2.8 Setting the heat curve
B
4
90
80
70
60
50
40
30
20
15
10
5
A
Outside temper-
ature °C
The figure shows the possible heat curves
of 0.1 to 4.0 for a target room temperature
of 20 °C. If, for example, heat curve 0.4 is
selected, a flow temperature of 40 °C is
maintained at an outdoor temperature of -
15 °C.
B
70
60
50
40
30
22
15
10
5
20
C
D
18
A
Outdoor temper-
ature °C
B
Target flow tem-
perature °C
If the heat curve 0.4 is selected and 21 °C
is specified for the target room temperat-
ure, the heat curve is then translated, as
0020323630_00 Operating and installation instructions
3.5
3
2.5
2
1.8
0
-5
-10
-15
-20
B
Target flow tem-
perature °C
0
-5
-10
-15
-20
C
Target room
temperature °C
D
Axis a
shown in the figure. The heat curve is dis-
placed according to the value of the tar-
get room temperature along axis a which
is angled at 45°. At an outdoor temperat-
ure of -15 °C, the control system provides
a flow temperature of 45 °C.
2.9 Display, control elements and
symbols
1.5
1.2
1.0
0.8
0.6
0.4
0.2
0.1
2.9.1 Control elements
A
– Calling up the menu
– Back to the main menu
– Confirming a selection/change
– Saving set values
– One level back
– Cancelling input
– Navigating through the menu struc-
ture
– Reducing or increasing the set
value
– Navigating to individual num-
bers/letters
– Calling up help
– Calling up the time programme as-
0.4
sistant
Active control elements light up green.
A
Press
once: You access the basic
display.
Press
twice: You access the menu.
2.9.2 Symbols
Time-controlled heating active
7

Publicidad

loading