OPERATION
CAUTION: DO NOT THROW ITEMS INTO THE STORAGE AREA. FAILURE TO HEED THESE
RECOMMENDATIONS COULD RESULT IN DAMAGE TO THE INTERIOR OF THE
CABINET.
The temperature in the cooler is automatically regulated by a set thermostat.
The position of the cooler, the ambient temperature, the number of times the lid is
opened and for how long the lid is opened are all factors affect the temperature in
the cooler. To assure proper temperature regulation do not place in the appliance
in sunlight or near / adjacent to a heat-radiating surface.
If your cooler is fitted with a lock, the key should be kept out of the reach of
children. If your new cooler is to replace an older one, which is not in use any
more, you should remove the lock mechanism on the old one, before disposing it.
The factory setting for the temperature range is 34°F to 38° F which keeps your
milk at a safe, cold temperature.
CONTROL PANEL SOLID-STATE THERMOSTAT
FRONT PANEL COMMANDS
SET
SET: To display target set point; in programming mode it selects a
parameter or confirms an operation.
DEF: To start a manual defrost
UP: To view the last alarm occurrence; in programming mode it browses
the parameter codes or increases the display value
DOWN: To view the last alarm occurrence; in programming mode it
browses the parameter codes or decreases the display value
Key Combination:
To lock & unlock the keyboard
To enter in programming mode
To return to the room temperature display
LED
MODE
On
Compressor enabled
Flashing
Anti-short cycle delay enabled (AC parameter)
On
Defrost in progress
Flashing
Dripping in progress
On
Fans output enabled
Flashing
Fans delay after defrost
On
Measurement unit
Flashing
Programming mode
On
Measurement unit
Flashing
Programming mode
3
MILK COOLER
FUNCTION
MAIN FUNCTIONS
1. How to See the Setpoint
1. Push and immediately release the SET key: the display will show the set
point value.
2. Push and immediately release the SET key or wait for 5 seconds to display
the sensor value again.
2. How to Change the Setpoint
1. Hold the SET key for more than 2 seconds to change the set point value.
2. The value of the set point will be displayed and the
3. To change the set value, push the
4. To set new point value, push the SET key again or wait 10 seconds.
3. How to Start a Manual Defrost
1. Hold the
key for more than 2 seconds and a manual defrost will start.
4. How to Lock the Keyboard
1. Hold the
and
keys for more than 3 seconds.
2. The "POF" message will be displayed and the keyboard will be locked. At
this point, it will be possible only to see the set point or the MAX or MIN
temperature stored.
3. If a key is pressed for more than 3 seconds, the "POF" message will be
displayed.
5. How to Unlock the Keyboard
1. Hold the
and
keys together for more than 3 seconds, until the "POF"
message is displayed.
ALARM SIGNALS
How to See the Alarm and Reset the Recorded Alarm
1. Push the
or
key to display the alarm signals.
2. When the signal is displayed, hold the SET key until the "rst" message is
displayed. Push the SET key again. The "rst" message starts blinking and the
normal temperature will be displayed again.
MESSAGE
CAUSE
"P1"
Room probe failure
"P2"
Evaporator probe failure
"HA"
Maximum temperature alarm
"LA"
Minimum temperature alarm
"dA"
Door open
"EA"
External alarm
"CA"
Serious external alarm (i1F=bAL)
"CA"
Pressure switch alarm (i1F=PAL)
LED starts blinking.
or
key within 10 seconds.
OUTPUTS
Compressor output according
to par. "Con" and "COF"
Defrost end is timed
Outputs unchanged
Outputs unchanged
Compressor and fans restarts
Output unchanged
All outputs OFF
All outputs OFF