Descargar Imprimir esta página

Kelvinator KCHMC34 Manual De Instrucciones página 4

Publicidad

Idiomas disponibles

Idiomas disponibles

MAINTENANCE
DANGER:
THE POWER MUST BE TURNED OFF AND THE UNIT DISCONNECTED FROM
THE POWER SOURCE WHENEVER PERFORMING SERVICE, MAINTENANCE
FUNCTIONS OR CLEANING THE REFRIGERATED AREA.
DANGER:
NEVER USE A HIGH PRESSURE WATER WASH FOR THIS CLEANING
PROCEDURE AS WATER CAN DAMAGE THE ELECTRICAL COMPONENTS
LOCATED NEAR OR AT THE CONDENSER COIL.
DANGER:
NEVER USE STEEL PADS, WIRE BRUSHES OR SCRAPERS!
CAUTION: NEVER USE AN ACID BASED CLEANING SOLUTION. MANY FOOD PRODUCTS
HAVE AN ACIDIC CONTENT WHICH CAN DETERIORATE THE FINISH. BE SURE
TO CLEAN THE STAINLESS STEEL SURFACES OF ALL FOOD PRODUCTS.
CLEANING STAINLESS STEEL INTERIOR AND EXTERIOR
Damage to stainless steel finish due to improper use of cleaning products or
non-recommended products is NOT covered under this product's warranty.
Use warm, soapy water and a soft, clean cloth or sponge
Rinse surfaces with clean, warm water and dry immediately to avoid water
spots
DO NOT USE:
Abrasive or harsh cleaners
Ammonia
Chlorine bleach
Concentrated detergents or solvents
Metal or plastic-textured scouring pads
Vinegar-based products
Citrus-based cleaners
Detergents that contain chlorine
Note: It suggested that the unit be emptied daily after all peak demand periods
have passed, and any remaining contents be placed in a storage refrigerator. The
unit should be unplugged and opened to allow it to defrost naturally. Let the unit
air dry after cleaning and plug the unit in to rebuild it frost layer at least 3 hours
to loading with product.
CLEANING THE CONDENSER FINS
To maintain proper refrigeration performance, the condenser coil must be free of
dust, dirt and grease. This will require periodic cleaning. Condenser fins should
be cleaned at least every month or as needed.
GASKET MAINTENANCE
Gaskets require regular cleaning to prevent mold and mildew build up and also
to keep the elasticity of the gasket. Gasket cleaning can be done with the use of
warm soapy water. Avoid full strength cleaning products on gaskets as this can
cause them to become brittle and prevent proper seals. Do not use sharp tools
or knives to scrape or clean the gasket which could possibly tear the gasket
and rip the bellows. Gaskets can easily be replaced and don't require the use of
tools or authorized service technicians. The gaskets are "Dart" style and can be
pulled out of the grove in the door and replaced by pressing the new one back
into place.
CHECK AFTER CLEANING
Check the unit again for safety. Check that the unit is operating properly. The lid
may be cleaned in the same way as the cooler. If a condenser and associated
fan are fitted at the back bottom of the cooler, they can gather dust and dirt. If
cleaning is necessary, they should be vacuumed with a soft brush. Please note
that the parts behind the protective grill can be hot and rotating.
4
MILK COOLER
POWER CORD
Please make sure that the power cord is connected to the proper voltage. The
power cord must be connected to a protected circuit with the correct voltage
and amperage.
Turn off the power switch before disconnecting the power cord, whenever
performing maintenance functions or cleaning the refrigerated cabinet.
Compressor warranties are void if compressor burns out due to improper voltage.
RE-STARTING
If disconnected, wait for 5 minutes before re-starting.
TROUBLE SHOOTING
If the cooler is in a place that is very hot or with bad ventilation, make sure to
provide adequate ventilation. If the condenser mentioned in Section Maintenance
is not clean, make sure to vacuum it. If the above points have been checked and
the cooler is still not working, please call service personnel. Inform them the nature
of the problem, the type of cooler, serial number and item number (provided on the
nameplate at the back of the cabinet).
SYMPTOMS
CAUSES
The unit is freezing
The temperature is set too
low to maintain safe, read to
serve product.
The unit does not
There is a power connection
refrigerate at all
failure problem.
The unit does not
The unit is in sunlight or near
refrigerate properly
a heating device.
The unit contains hot or too
much product.
The unit door is opened too
frequently or left open to long.
The condenser is clogged.
There is a loud noise
The floor is too weak or
the leveling feet are set
incorrectly.
The back-side of the unit is
too close to the wall.
The tray is not in the correct
position.
There is condensation
High-moisture air can
on the exterior of the
produce condensation on an
unit
external surface.
Ice is covering the
Ice is an insulator; the unit
interior walls and the
has built up ice and needs to
unit is to warm
be defrosted.
The interior walls are
Unit has not been on long
not frosted
enough are refrigeration
system needs attention
Door doesn't close
The door is bent.
tightly
The unit has a leveling issue.
The door gasket has come
out.
SOLUTIONS
Turn the temperature
dial to a warmer setting
– allow 2 hours for unit
to reach steady state
condition and confirm
product temperature is
within the 34° to 40°F
ideal holding range.
Check the power cord
to make sure the unit is
plugged in it correctly.
Check the installation
place Move away from
sunlight or away from
heater.
Check the condition of the
product when the cooler
was loaded.
Check the temperature
control setting.
Check the installation and
adjust the tray position.
Wipe with a dry cloth.
Empty unit and put
the milk cartons in a
refrigerator and unplug
unit so it can completely
defrost with the lid / cover
open.
Wait 2 hours for frost to
develop, if it doesn't call
for service.
Level the unit again.
Reposition the gasket.

Publicidad