Modello - Modèle - Model
Modell - Modelo - Modelo
Fabbricante - Constructeur - Manufacturer
Hersteller - Fabricante - Fabricante
8.1
Controller EW974EO
HC(Eliwell)
1
5
6
2
9
11
1. Up Arrow
2. Up Arrow
3. Stand-by/Esc
4. Setpoint
5. Compressor
6. Defrost
7. Alarm
8. °F
9. Reduced set/Level 2 parameters
10. °C
11. Fan
12. Aux
Modification of Setpoint
• Press and instantly release the button
"Setpoint"(4).
• SET appears on the display.
• To change the value, act on the keys within
15 seconds "Up Arrow" (1)(to increase) or
"Up Arrow" (2)(to decrease).
• Press the button again "Setpoint"(4) and
the value of appears on the display
Setpoint.
Manual cycle start Defrost
• Press the button "Up Arrow" (1) for 5
seconds. If the conditions for defrosting
do not exist, the display flashes 3 times to
indicate that the operation will not be
carried out.