IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
All electrical work must be performed by a licensed electrician
and conform to all national, state, provincial and local codes.
When installing and using this electrical equipment, basic safety
precautions should always be followed, including the following:
Modifications made to this equipment, which are not authorized by the
manufacturer, may void the user's authority to operate this equipment.
Risk of electric shock which can result in serious injury or death: Before
attempting to install or service, ensure that all power to the circuit supplying
power to the system is disconnected or turned off at the circuit breaker. All wiring
must be done in accordance with the National Electrical Code® (NEC)®, NFPA-
70®, including those in Article 680 - Swimming Pools, Fountains, and Similar
Installations.
In Canada, the Canadian Electrical Code (CEC), CSA C22.1, must be followed.
All applicable local installation codes and regulations must be followed.
A terminal bar marked "GROUND" is provided within the power center. To reduce
the risk of electrical shock, connect this terminal bar to the grounding terminal
of your electric service or supply panel with a continuous copper conductor
having green insulation and one that is equivalent in size to the circuit conductors
supplying this equipment, but no smaller than no. 12 AWG (3.3 mm2). In addition,
a second wire connector should be bonded with a no. 8 AWG (8.4 mm2) copper
wire to any metal ladders, water pipes, or other metal within five (5) feet (1.52
m) of the pool/spa. In Canada, the bonding wire must be minimum 6 AWG (13,3
mm2).
LED Light Controller | Spare Parts Installation Manual
WARNING
WARNING