ADDITIONAL FUNCTIONS: can be achieved by the A and B outputs through one or more access codes
Connect the main PCB to the control box (Pic. 8) or to the external control relay, then store an access code with required outputs.
Different functions can be achieved by one or both of the outputs, but different access codes to one relay carry out the same function.
NOTE WELL: in the presence of a power black-out, the individual functions are reset and remain stored on the receiver.
OUTPUT DELAY
The pulse is delayed (for a number
of minutes) after pressing the access
code.
Programming:
1) Set DIP-sw. 5 to ON. The red led 1 on the PCB flashes.
2) Press the number of minutes corresponding to the activation delay as
required (max.1439 minutes).
3) Press output A or B through which the required function is activated.
4) Confirmation of the operation: beep and green led alight for 2 s.
5) Set all the DIP-switches to OFF.
Using the function:
Press the access code followed by A or B as programmed. The green led goes on
for 1 s followed by an activation beep. The blue led starts flashing and indicates
that the function has been activated.
TIMED WITH 2 PULSES
A pulse is given after the access code
has been pressed and another one is
given after a set time (minutes).
Programming:
1) Set DIP-sw. 6 to ON. The red led 1 on the PCB flashes.
2) Press the number of minutes for the time required after the first pulse
(max. 1439 minutes).
3) Press either A or B output by which the function is to be activated.
4) Confirmation of the operation: beep and green led alight for 2 s.
5) Set all the DIP-switches to OFF.
Using the function:
Press the access code followed by A or B as programmed. The green led goes on
for 1 s followed by an activation beep. The blue led starts flashing and indicates
that the function has been activated.
BISTABLE
Each pulse by the access code energizes or
de-energizes the output relay.
Programming:
1) Set DIP-sw. 7 to ON. The red led 1 on the PCB flashes.
2) Press only the button key No. 7.
3) Press either A or B output by which the required function is to be actived.
4) Confirmation of the operation: beep and green led alight for 2 s.
5) Set all the DIP-switches to OFF.
Using the function:
Press the access code followed by A or B as programmed.
The green led goes on for 1 s followed by an activation beeping.
TIMED DELAY
Each pulse by the access code
delays (for a number of minutes)
the energizing of the timed relay.
Programming:
1) Set DIP-sw. 8 to ON. The red led 1 flashes.
2) Press the number of minutes for the delay with time 1 (max 1439 minutes).
3) Press either A or B output by which the required function is to be activated.
4) Confirmation of the operation: beep and green led alight for 2 s.
5) Press the numer of minutes for time 2 (max. 1439 minutes).
6) Press ether A or B as set in step 3).
7) Confirmation of the operation: beep and green led alight for 2 s.
8) Set all the DIP-switches to OFF.
Using the function:
Press the access code followed by A or B as programmed.
The green led goes on for 1 s followed by an activation beep.
The blue led starts flashing and indicates that the function has been activated.
DIGITAL KEYPAD
pulse
output
Time
pulse
output
Time
pulse
output
pulse
output
Time 1
Time 2
12
Diagram
1)
2)
ON
5
main PCB
time in minutes
(max 1439 = 24h)
In order to RESET (temporary cancellation of the function) press the following
sequence:
A or B - access code - A or B
The green led goes on for 1 s followed by a confirmation beep, while the
blue led stays illuminated.
Diagram
2)
1)
ON
6
main PCB
time in minutes
(max 1439 = 24h)
In order to RESET (temporary cancellation of the function) press the following
sequence:
A or B - access code - A or B
The green led goes on for 1 s followed by a confirmation beep, while the
blue led stays illuminated.
Diagram
2)
1)
ON
7
main PCB
press key 7
Diagram
1)
2)
3)
ON
time 1 in
minutes
(max 1439)
8
main PCB
keypad
A or B output keypad
In order to RESET (temporary cancellation of the function) press the following
sequence:
A or B - access code - A or B
The green led goes on for 1 s followed by a confirmation beep, while the
blue led stays illuminated.
3)
4)
ALL DIP-SW.
TO OFF
or
5
OFF
A or B output
main PCB
3)
4)
ALL DIP-SW.
TO OFF
or
6
OFF
A or B output
main PCB
3)
4)
ALL DIP-SW.
TO OFF
or
7
OFF
A or B output
main PCB
4)
5)
time 2 in
or
minutes
or
(max 1439)
6)
ALL DIP-SW.
TO OFF
8
OFF

Publicidad