ADDITIONAL FUNCTIONS: can be achieved by the A and B outputs through one or more access codes
TIMED BISTABLE
The relay is energized and remain
energized for the time as set (in minutes).
Programming:
1) Set DIP-sw. 9 to ON. The red led 1 on the PCB flashes.
2) Press the number of minutes corresponding to the activation time as
required (max. 1439 minutes).
3) Press output A or B as required for the function to be activated.
4) Confirmation of the operation: beep and green led alight for 2 s.
5) Set all the DIP-switches to OFF.
Using the function:
Press the access code followed by A or B as programmed.
The green led goes on for 1 s followed by an activation beep.
The blue led starts flashing and indicates that the function has been activated.
REMOVING THE ADDITIONAL FUNCTIONS
Steps to cancel the additional functions from the single relay.
1) Set DIP-sw. 5 to ON. The red led 1 on the PCB flashes.
2) Press A (or B) - access code - press A (or B).
3) Press either A or B output by which the required function is to be activated.
4) Confirmation of the operation: beep and green led alight for 2 s.
5) Set all the DIP-switches to OFF.
OVERALL DIMENSIONS
Ø56
29
25
54
Recess mount keypad
TECHNICAL DATA
Power supply 2x0,5 mm²
Connections to the keypad
Keypad absorption
Stand-by relay absorption
Energized relay absorption
Working temperature
N.O. channels
N.C. channels
Communication distance
Output contacts
Keypad protection standards
PCB protection standards
DIGITAL KEYPAD
pulse
output
Time
74
72 mm
Keypad
12-24 Vac/dc
4 x 0,5 mm²
15 mA
4 mA
27 mA
-20 °C + 80 °C
2
1
max 100 m
1 A - 120 V - 60 VA
IP 54
IP 53
13
Diagram
1)
2)
ON
9
main PCB
time in minutes
(max 1439 = 24h)
In order to RESET (temporary cancellation of the function) press the following
sequence:
A or B - access code - A or B
The green led goes on for 1 s followed by a confirmation beep, while the
blue led stays illuminated.
Diagram
1)
2)
ON
or
5
main PCB
A or B output
ACCESS
CODE
gree led
BEEP
for 2 seconds
40
Surface mount
keypad
3)
4)
ALL DIP-SW.
TO OFF
or
9
OFF
A or B output
main PCB
3)
ALL DIP-SW.
TO OFF
or
5
A or B output
main PCB
73