SYMPTOM
POSSIBLE
CAUSE(S)
CORRECTIVE
ACTION
Motor will not run
1. Defective
plug, cord,
switch
or motor
1. Check
wiring,
replace
defective
parts
2. Blown fuse
or circuit
breaker
2. Check
fuse or breaker,
replace
Excessive
dust in air
1. Leaking
bag or hose connection
1. Check filter and collector
bag connections.
Check
collector
hose connections
2. Filter or collector
bag leaks
2. Dust trapped
under
bag clamp or collector
bag not
sealed
on collar
Excessive
impeller
noise
Excessive
motor noise
Motor fails to develop
full
power
or motor stalls
1. Large
debris
or piece or wood
in
impeller
housing
2. Loose
impeller
1. Do not vacuum
metal
materials.
Turn
collector
off and let debris
settle
in
collector
bag.
2. Disconnect
collector
from power
source.
Remove
four screws
holding
motor/fan
assembly
to
upper
blower
housing.
Carefully
lift out motor/fan
assembly
and lay on workbench.
Hold
motor shaft from
turning
using vise grips and tighten
bolt holding
impeller.
Defective
motor
Have
motor checked
by qualified
motor
service
technician
1. Low voltage
to collector
caused
by
circuit
overload
2. Low voltage
to collector
caused
by
undersized
extension
cords
3. Low voltage
from power
source
1. Remove
other electric
machines
or
appliances
from circuit
2. Increase
wire gauge
size of extension
cords or shorten
extension
cords
3. Request
voltage
check from power
company
4. Replace
motor capacitor
1. Check
motor,
replace
if necessary
4. Defective
motor capacitor
Motor slow to start
or fails
1. Burned
or defective
motor
to reach
full speed
2. Defective
motor capacitor
switch
2. Check
switch,
replace
if necessary
Motor overheats
1. Motor overload
1. Reduce
lead by slowing
dust production
2. Improper
motor cooling
2.Clean
sawdust
from
motor
Tripping
circuit
breaker
or
1. Motor overloaded
1. Reduce
load by slowing
dust production
fuses
2. Improper
capacity
of circuit
breaker
2. Use proper
capacity
circuit
breaker
or
or fuses
fuse

Publicidad

loading