Connecting Cables to Inverter / Verbindungskabel zum Wechselrichter/ Branchement
des câbles à l'onduleur/ Conexión de cables al inversor/ Ligar os Cabos ao
Inversor/ Kabels aansluiten op de omvormer / Collegamento dei cavi all'inverter /
Podłączanie przewodów do falownika / Připojení kabelů ke střídači / Anslutning av
kablar till växelriktare / Conectarea cablurilor la invertor / Свързване на кабелите към
инвертора / Tilslutning af kabler til inverteren / Σύνδεση καλωδίων στον μετατροπέα
/ Kaablite ühendamine muunduriga / Kaapelien kytkeminen invertteriin / Spajanje
kabela na izmjenjivač / Kábelek csatlakoztatása az inverterhez / Kabelių jungimas
prie inverterio / Kabeļu pievienošana uz invertoru / Pripojenie kabeláže do invertora /
Priključitev kablov na pretvornik / Kabloların İnvertöre Bağlanması: / Conectando os
Cabos ao Inversor
Cable connection from BMS Parallel box- Ⅱ G2 to the
inverter:
"BAT+" to "BAT+";
"BAT-" to "BAT-";
"BMS" to "BMS".
To Inverter
* It is recommended to protect the cables by using corrugated pipe.
* If you plug the cable into the wrong port, you can insert the power cable disassembling
tool into the gap on the side of the joint to unplug the cable easily.
* Please refer to "battery connection" section of the inverter's user manual/quick
installation guide for details about inverter connection.
•
If the connector of the T-BAT-SYS-HV-3.0 controller does not match the connector
provided with the accessory cable, you can trim the blue connector and replace it with a
black connector. The replacement should follow the rule of male-to-male and female-to-
female connections. The Installation mode of black connector is as follows:
①
screw connection
DC socket housing(-)
• Wire order for the BMS Communication Cable (the parallel box to the inverter)
Sequence
BMS
BMS
BAT-
BAT+
BMS
BAT- BAT+
②
screw connection
DC socket housing(+)
1
2
/
GND
Remember to always keep the unused port plugged.
slave
spring
③
chamber
3
4
/
BMS_H
BMS_L
main
inverter
④
wire strands
5
6
/
7
8
A1
B1
81