3.3 CONNECTING THE DEVICE
3.3.1 CONNECTING THE POWER
Connection of the device must be performed by a qualified person. In addition, a person with required
qualifications should check if the earthing or electrical installation with protection system is in line with
the safety regulations and if they operate correctly.
The device must be placed near the work station.
Connection of excessively long conduits to the machine must be avoided.
One-phase welders should be connected to the socket fitted with an earthing prong.
Welders powered from a 3-Phase network are delivered without a plug, the plug must be obtained
independently and installation should be assigned to a qualified person.
PLEASE NOTE: THE DEVICE MAY ONLY BE USED UPON CONNECTION TO AN
INSTALLMENT WITH A PROPERLY FUNCTIONING FUSE!
4.
OPERATION
4.1 MACHINE DESCRIPTION
S-SPOTTER 3500
11
12
1
13
14
5
4
3
2
6
7
8
9
10
Component elements (may vary from depending on the model).
3
4
5
1
1.
Working handle (gun)
2.
Carbon arc nozzle
3.
Nozzle for washers
4.
Nozzle for bolts, pins, etc.
5.
Electrode for one sided welding
6.
Electrode with a flat pin for welding zigzag wires
7.
Hammer with a nozzle for welding washers / hook for pulling dents
14
1.
LCD display
2.
Reduce power
3.
Increase power
4.
Reduce time
5.
Increase time
6.
Mode selection
7.
Earth cable
8.
Socket for gun lead
9.
Gun test button
10. Control socket
11. ON/OFF switch
12. Fuse
13. Power cable
14. MAN – Press the gun's trigger to start welding.
AUTO – there is no need to press the gun's trigger
to start welding. Welding starts automatically after
the gun's electrode touches the welded surface.
2
6
7
Rev. 23.11.2018
4.2 DEVICE OPERATING MODES
Function
Description
Model
Welding triangular washers
Welding washers
Welding pins/bolts etc.
One sided welding
Zigzag wire welding
Swelling – hearing up sheet metal using a
carbon arc
Sheet metal overlap welding
Carbon arc heating and shrinking
Carbon arc cutting
* FFF means unlimited time
** FF means maximum current
4.3 CONNECTING THE DEVICE
The machines are powered by two phase 400 V alternating current. Plug connection diagram:
not connected
connected
L3
L2
L1
N
connected
not connected
PE
connected
4.3.1 CONNECTING EARTH
1
2
Rev. 23.11.2018
EN
Time range*
Power range**
S-SPOTTER 3500
S-SPOTTER 3500
0,01 – FFF
25 – FF
0,01 – FFF
25 – FF
0,01 – FFF
25 – FF
0,01 – FFF
25 – FF
0,01 – FFF
25 – FF
FFF
25 – FF
FFF
25 – FF
FFF
25 – FF
FFF
25 – FF
Green-yellow wire is used to connect the PE
earth cable. The two phases should be connected
to L1 and L2. Phase three L3 and neutral N
connections remain unconnected in the plug. A
qualified electrician is required to perform these
connections.