HOW TO TEST THE BATTERY
1
Light
Setup
PSI KG/CM BAR
Light
TARGET
Setup
Press and hold the power switch (8) for
3 seconds to turn on the unit.
3
LCD
LOW
Charge immediately
Power
M
Unit
Inflator
TEST
3 Seconds
LOWMIDDLEFULL
2
V
%
Power
READYOVERLOAD
COOLING
M
Unit
Inflator
TEST
Check the battery status
LCD
LCD
MIDDLE
V
V
OK
GOOD
2
Follow the steps below for jump start,
otherwise it could be dangerous:
1. Insert the jumper cable (16) into the jump
start port (1) of the device.
2. Connect the red (+) clamp to the positive
(+) battery terminal.
3. Connect the black (-) clamp to the metal
part of the engine (negative ground) or to
the negative battery terminal.
Press "Battery test" button and the battery voltage
and status will show in the LCD.
Top on the
FULL
LCD
V
LOW
MIDDLE
FULL
64
Battery range Result
<11.7V
Charge the battery
immediately or
replace the battery
11.7≤V<12.5
Battery is ok and
charge if possible
V≥12.5
Battery is good