Descargar Imprimir esta página
Pleasant Hearth VFL2-RW18DT Manual Del Usuario
Pleasant Hearth VFL2-RW18DT Manual Del Usuario

Pleasant Hearth VFL2-RW18DT Manual Del Usuario

Conjunto de leños a gas de tiro natural

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

WARNING: This appliance
is equipped for (Natural and
Propane) gas. Field conversion is
not permitted other than between
natural or propane gases.
CAUTION - FOR YOUR SAFETY
WARNING: IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
- Do not store or use gasoline or other flammable vapors and Iiquids in vicinity of this or any other
appliance.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone. Follow the gas
supplier's instructions.
• If you cannot reach your gas supplier, call the fire department.
- Installation and service must be performed by a qualified installer, service agency or the gas supplier.
WARNING: Do not attempt to access or change the setting of the fuel selection means. Access
to and adjustment of the fuel selection means must only be a performed by a qualified service
person when connecting this appliance to a specified fuel supply at the time of installation.
Change of the selector setting to other than the fuel type specified at the time of installation could
damage this appliance and render it inoperable.
The installer shall replace the access cover before completing the installation and operating this
appliance.
This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed.
Provisions for adequate combustion and ventilation air must be provided. Refer to Air For
Combustion and Ventilation section on page 9 of this manual.
This appliance may be installed in an aftermarket, permanently located manufactured (mobile) home,
where not prohibited by local codes. This appliance is only for use with propane or natural gas.
This appliance is equipped with a simple means to switch between propane and natural gas. Field
conversion by any other means including the use of a kit is not permitted.
The Installation instructions for an appliance for installation on combustible flooring shall specify that
when the appliance is installed directly on carpeting, tile or other combustible material, other than wood
flooring, the appliance shall be installed on a metal or wood panel extending the full width and depth of
the appliance.
Questions, problems, missing parts? Before returning to your retailer, call our customer service
department at 1-877-447-4768, 8:30 a.m. – 4:30 p.m., CST, Monday – Friday or email us at
customerservice@ghpgroupinc.com.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
1
VENT-FREE
GAS LOG SET
MODEL # VFL2-SO18DT
VFL2-EO18DT
VFL2-SO24DT
VFL2-EO24DT
VFL2-WW18DT
VFL2-RW18DT
VFL2-WW24DT
VFL2-RW24DT
Patent Pending Dual
Fuel System
NG
LP
Dual Fuel
ANS Z21.11.2 2016
80-10-442 - 2019-01-09
US

Publicidad

loading

Resumen de contenidos para Pleasant Hearth VFL2-RW18DT

  • Página 1 VENT-FREE GAS LOG SET MODEL # VFL2-SO18DT VFL2-EO18DT VFL2-SO24DT VFL2-EO24DT VFL2-WW18DT VFL2-RW18DT WARNING: This appliance VFL2-WW24DT is equipped for (Natural and VFL2-RW24DT Propane) gas. Field conversion is not permitted other than between Patent Pending Dual natural or propane gases. Fuel System...
  • Página 2 Failure to follow these instructions may result in possible injury to persons or a fire hazard and will void the warranty. ITEM VFL2-SO24DT VFL2-SO18DT VFL2-EO24DT VFL2-EO18DT VFL2-WW24DT VFL2-WW18DT VFL2-RW18DT VFL2-RW24DT Input Rating 30,000 BTU/Hr 30,000 BTU/Hr Minimum Input Rating 15,000 BTU/Hr 24,000 BTU/Hr 15,000 BTU/Hr...
  • Página 3 IMPORTANT SAFETY INFORMATION IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, operate, or service this heater. Improper use of this heater can cause serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning. WARNING: FIRE, EXPLOSION, AND ASPHYXIATION HAZARD Improper adjustment, alteration, service, maintenance, or installation of this heater or its controls can cause death or serious injury.
  • Página 4 SAFETY INFORMATION 1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases. 2. Do not place propane/LP supply tank(s) inside any structure. Locate propane/LP supply tank(s) outdoors. 3.
  • Página 5 PRODUCT IDENTIFICATION Log Locator Spacer - (4) NG ODS Pilot LP ODS Pilot Grate Cap Burner Tube Battery Ignitor Thermostatic Control Valve Grate...
  • Página 6 PRODUCT FEATURES This log set has been tested and approved to ANS Z21.11.2 2013 standard for Unvented Heaters and can be operated with the flue damper closed. State and local codes in some areas prohibit the use of vent-free heaters. DUAL FUEL CAPABILITY Your heater is equipped to operate on either propane or natural gas.
  • Página 7 PREPARING FOR INSTALLATION WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM HEATERS Water vapor is a by-product of gas combustion. An unvented room heater produces approximately one (1) ounce (30 mL) of water for every 1,000 BTUs (.3 kw) of gas input per hour.
  • Página 8 PREPARING FOR INSTALLATION DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms.
  • Página 9 PREPARING FOR INSTALLATION WARNING: If the area in which the heater may be operated does not meet the required volume for indoor combustion air, combustion and ventilation air shall be provided by one of the methods described in the NATIONAL FUEL GAS CODE, ANSI Z223.1/NFPA 54, the INTERNATIONAL FUEL GAS CODE, or applicable local codes.
  • Página 10 INSTALLATION NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your primary heating system. Do not install this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circulate the heat throughout the house.
  • Página 11 INSTALLATION CHECK GAS TYPE Make sure your gas supply is correct for your log set. If supply is not correct, do not install heater. Call dealer where you purchased heater for proper gas log set. LOG SIZING REQUIREMENTS Log Size Minimum Firebox Size Height Depth...
  • Página 12 INSTALLATION MINIMUM NONCOMBUSTIBLE MATERIAL CLEARANCE If Not Using Mantel You must have noncombustible material(s) above the fireplace opening. Noncombustible materials (such as slate, marble, tile, etc.) must be at least 1/2 in. thick. With sheet metal, you must have noncombustible material behind it, such as a noncombustible fireplace hood accessory.
  • Página 13 INSTALLATION MANTEL CLEARANCES In addition to meeting noncombustible material clearances, you must also meet required clearances between fireplace opening and mantel shelf. If the clearances listed below are not met, you will need to raise the mantel. Determining Mantel Clearances If you meet minimum clearance requirements between mantel shelf and top of fireplace opening, your installation (see Fig.
  • Página 14 INSTALLATION FLOOR CLEARANCES a) If installing appliance on floor level, you must maintain the minimum distance of 14 in. to combustibles (see Fig. 9). b) If combustible materials are less than 14 in. to the fireplace, you must install appliance at least 5 in.
  • Página 15 INSTALLATION WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury. Before beginning assembly or operation of the product, make sure all parts are present. Compare parts with package contents list.
  • Página 16 INSTALLATION GAS SELECTION INSTRUCTIONS WARNING: This appliance can be used with propane or natural gas. It is shipped from the factory adjusted for use with propane. CAUTION: The knob to the gas selection means shall not be accessed or adjusted while the appli- ance is in operation.
  • Página 17 INSTALLATION CONNECTING TO GAS SUPPLY WARNING: A qualified service technician must connect heater to gas supply. Follow all local codes. CAUTION: Never connect heater directly to the gas supply. This heater requires an external regulator (not supplied). The external regulator between the gas supply and heater must be installed. Gas supplier provides external regulator for natural gas.
  • Página 18 INSTALLATION CAUTION: Use pipe joint sealant that is resistant to gas (PROPANE or NG). We recommend that you install a sediment trap in a supply line. Locate sediment trap where it is within reach for cleaning and not likely to freeze. Install in the piping system between fuel supply and heater.
  • Página 19 INSTALLATION CHECKING GAS CONNECTIONS WARNING: Test all gas piping and connections for leaks after installing or servicing. Correct all leaks immediately. WARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints.
  • Página 20 INSTALLATION BEFORE INSTALLING THE APPLIANCE - Turn off gas supply to fireplace or firebox. - Clean fireplace floor and chimney before installing log set. Seal any ash. Clean out doors to protect the unit from down drafts. MOUNTING PROCEDURE - Place grate/burner assembly into firebox with the front pan facing forward. - Drill two (2) 5/32"...
  • Página 21 ASSEMBLING LOGS VFL2-SO18DT / VFL2-EO18DT / VFL2-SO24DT / VFL2-EO24DT WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury. CAUTION: After installation and peridically thereafter, check to ensure that no yellow flame comes in contact with any log.
  • Página 22 ASSEMBLING LOGS VFL2-WW18DT / VFL2-RW18DT / VFL2-WW24DT / VFL2-RW24DT WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury. CAUTION: After installation and peridically thereafter, check to ensure that no yellow flame comes in contact with any log.
  • Página 23 OPERATION FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by the electronic ignitor. When lighting the pilot, follow these instructions exactly.
  • Página 24 OPERATION LIGHTING INSTRUCTIONS 1. STOP! Read the safety information above. 2. Turn control knob clockwise to the “OFF” position (See Fig. 25). 3. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety informa- tion above.
  • Página 25 OPERATION INSPECTING BURNERS Check pilot flame pattern and burner flame patterns often. PILOT FLAME PATTERN Figure 27 shows a correct pilot flame pattern. Figure 28 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down.
  • Página 26 CARE AND MAINTENANCE BURNER FLAME PATTERN Figure 29 shows a correct burner flame pattern. Figure 30 shows an incorrect burner flame pattern. The incorrect burner flame pattern shows sporadic, irregular flame tipping. The flame should not be dark or have an orange/reddish tinge. Note: When using the heater the first time, the flame will be orange for approximately one hour until the log cures.
  • Página 27 CARE AND MAINTENANCE 1. Shut off unit including pilot. Allow unit to cool for at least 30 minutes. 2. Inspect burner, pilot and primary air inlet holes on orifice holder for dust and dirt (See Fig. 31). 3. Blow air through the ports/slots and holes in the burner. 4.
  • Página 28 TROUBLESHOOTING WARNING: If you smell gas: • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. •...
  • Página 29 TROUBLESHOOTING PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION 1. Control knob is not fully 1. Press in control knob fully. ODS/pilot lights pressed in. but flame goes out 2. Control knob is not pressed 2. After ODS/pilot lights, keep control when control knob is in long enough.
  • Página 30 TROUBLESHOOTING PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION 1. Turn heater off when using furniture White powder resi- 1. When heated, the vapors due forming within from furniture polish, wax, polish, wax, carpet cleaner or similar burner box or on carpet cleaners, etc., turn products.
  • Página 31 REPLACEMENT PARTS LIST For replacement parts, call our Technical Service Department at 1-877-447-4768, 8:30 a.m. – 4:30 p.m., CST, Monday – Friday. VFL2-SO18DT/ VFL2-EO18DT/ VFL2-SO24DT/ VFL2-EO24DT VFL2-WW18DT/ VFL2-RW18DT/ VFL2-WW24DT/ VFL2-RW24DT PART NO. ITEM NO. DESCRIPTION VFL2-SO18DT VFL2-SO24DT VFL2-WW18DT VFL2-WW24DT VFL2-RW18DT...
  • Página 32 This limited warranty is extended to the original retail purchaser of this heater and warrants against any years years 32 33...
  • Página 33 GHP Group, Inc. 6440 W Howard S Niles, IL 60714-3302 Tel: (877) 447-4768 www.ghpgroupinc.com GHP Group, Inc. 6440 W Howard St Niles, IL 60714-3302...
  • Página 34 DE TIRO NATURAL NÚM. DE MODELO VFL2-SO18DT VFL2-EO18DT VFL2-SO24DT VFL2-EO24DT VFL2-WW18DT ADVERTENCIA: Este aparato VFL2-RW18DT VFL2-WW24DT está equipado para gas (Natural y VFL2-RW24DT Propano). La conversión de campo Pendiente de patente no está permitida a menos que sea Sistema de Compustible Dual entre gas natural o gas propano.
  • Página 36 VFL2-SO18DT VFL2-SO24DT VFL2-EO18DT VFL2-EO24DT VFL2-WW18DT VFL2-WW24DT ARTÍCULO VFL2-RW18DT VFL2-RW24DT 30,000 BTU/Hr 30,000 BTU/Hr Capacidad nominal de entrada 15,000 BTU/Hr 24,000 BTU/Hr 15,000 BTU/Hr 24,000 BTU/Hr Capacidad de entrada mínima Tipo de gas...
  • Página 37 INFORMACIÓN DE SEGURIDAD IMPORTANTE IMPORTANTE: Por favor, lea cuidadosa y completamente este manual del propietario antes de intentar ensamblar, operar o darle servicio a este calefactor. El uso inapropiado de este calefactor puede causar lesiones graves o la muerte por quemaduras, incendio, explosión, choque eléctrico y envenenamiento por monóxido de carbono. ADVERTENCIA: PELIGRO DE INCENDIO, EXPLOSIÓN Y ASFIXIA La alteración, el ajuste, servicio, mantenimiento o la instalación inadecuada de este calentador o sus controles pueden causar lesiones graves o incluso la muerte.
  • Página 38 INFORMACIÓN DE SEGURIDAD 1. Este aparato es solo para ser usado con el tipo de gas indicado en la placa de características. Este aparato no es convertible para uso con otros gases. 2. No coloque el(los) tanque(s) de suministro de propano/PL dentro de ninguna estructura. Coloque el(los) tanque(s) de suministro de propano/PL en exteriores.
  • Página 39 IDENTIFICACIÓN DEL PRODUCTO Separador Log Locator localizador Spacer - (4) de la rejilla Pilot ODS NG ODS Pilot de GN Tapa de LP ODS Pilot Grate Cap Pilot ODS de PL rejilla Tubo del Burner Tube Quemador Encendedor Battery Ignitor Electrónica de botón de presión (batería)
  • Página 40 CARACTERÍSTICAS DEL PRODUCTO Este conjunto de leños ha sido probado y aprobado por la norma ANS Z21.11.2 2013 para Calefactores no ventilados y pueden ser operados con el regulador de tiro del conducto cerrado. Los códigos estatales y locales en algunas áreas prohíben el uso de calefactores de tiro natural.
  • Página 41 PREPARACIÓN PARA LA INSTALACIÓN VAPOR DE AGUA: UN SUBPRODUCTO DE CALEFACTORES NO VENTILADOS DE HABITACIÓN El vapor de agua es un subproducto de la combustión del gas. Un calefactor no ventilado de habitación produce aproximadamente una (1) onza (30 mL) de agua por cada 1,000 BTU (3 Kw) de entrada de gas por hora. Un calefactor no ventilado de habitación está...
  • Página 42 PREPARACIÓN PARA LA INSTALACIÓN DETERMINACIÓN DEL FLUJO DE AIRE FRESCO A LA UBICACIÓN DEL CALEFACTOR Determinación de si tiene un espacio confinado o no confina Use esta hoja de cálculo para determinar si tiene un espacio confinado o no confinado. Espacio: Incluye la habitación en la cual instalará...
  • Página 43 PREPARACIÓN PARA LA INSTALACIÓN ADVERTENCIA: Si el área en la cual puede ser operado el calefactor no cumple el volumen requerido para aire de combustión de interiores, el aire de combustión y ventilación será proporcionado por uno de los métodos descritos en el NATIONAL FUEL GAS CODE, ANSI Z223.1/NFPA 54, el INTERNATIONAL FUEL GAS CODE, o los códigos locales aplicables.
  • Página 44 INSTALACIÓN AVISO: Este calefactor está diseñado para ser usado como calor complementario. Use este calefactor junto con su sistema de calefacción primario. No instale este calefactor como su fuente primaria de calor. Si tiene un sistema de calefacción central, puede poner a funcionar un soplador de circulación del sistema mientras usa el calefactor.
  • Página 45 INSTALACIÓN COMPRUEBE EL TIPO DE GAS Asegúrese de que su suministro de gas sea el correcto para su conjunto de leños. Si el suministro no es el correcto, no instale el calefactor. Llame al concesionario donde compró el calefactor para obtener el conjunto de leños a gas apropiado.
  • Página 46 INSTALACIÓN ESPACIO LIBRE MÍNIMO DEL MATERIAL NO COMBUSTIBLE Si no está usando marco Debe tener material(es) no combustible(s) sobre la abertura de la chimenea. Los materiales no combustibles (como pizarra, mármol, baldosa, etc.) deben ser de al menos 1/2 pulg. de grosor. Con hojas de metal, debe tener material no combustible detrás de él, como un accesorio de extractor de chimenea no combustible.
  • Página 47 INSTALACIÓN ESPACIOS LIBRES DEL MARCO Además de cumplir con los espacios libres del material no combustible, también debe cumplir con los espacios libres entre la abertura de la chimenea y la repisa del marco. Si no se respetan las distancias que figuran a continuación, será necesario elevar el marco. Determinación de los espacios libres del marco Si se respetan los requisitos de distancia mínima entre la repisa del marco y la parte superior de la abertura del hogar, no será...
  • Página 48 INSTALACIÓN ESPACIOS LIBRES DEL PISO a) Si está instalando el aparato al nivel del piso, debe mantener la distancia mínima de 14 pulg. a los combustibles (ver Fig. 9). b) Si los materiales combustibles están a menos de 14 pulg. de la chimenea, debe instalar el aparato al menos a 5 pulg.
  • Página 49 INSTALACIÓN ADVERTENCIA: No colocar las piezas de acuerdo con estos diagramas o no usar solamente piezas específicamente aprobadas con este calefactor puede resultar en daños a la propiadad o lesiones personales. Antes de comenzar a ensamblar u operar este producto, asegúrese de que todas las piezas estén presentes. Compare las piezas con la lista de contenido del paquete.
  • Página 50 INSTALACIÓN INSTRUCCIONES DE SELECCIÓN DEL GAS ADVERTENCIA: Este aparato puede ser usado con propano o gas natural. Es enviado de la fábrica ajustado para ser usado con propano. PRECAUCIÓN: No se debe acceder a ni ajustar la perilla para los medios de selección del gas mientras el aparato esté en operación.
  • Página 51 INSTALACIÓN CONEXIÓN AL SUMINISTRO DE GAS ADVERTENCIA: Un técnico de servicio calificado debe conectar el calefactor al suministro de gas. Siga todos los códigos locales. PRECAUCIÓN: Nunca conecte el calefactor directamente al suministro de gas. Este calefactor requiere un regulador externo (no suministrado).
  • Página 52 INSTALACIÓN PRECAUCIÓN: Use sellador de juntas de tubo que sea resistente al gas (PROPANO O GN). Recomendamos que instale una trampa de sedimentos en una línea de alimentación. Ubique la trampa de sedimentos donde esté al alcance para limpieza y que no existan probabilidades de que se congele. Instálela en el sistema de tuberías entre el suministro de combustible y el calefactor.
  • Página 53 INSTALACIÓN REVISIÓN DE LAS CONEXIONES DE GAS ADVERTENCIA: Pruebe toda la tubería y conexiones de gas en contra de fugas después de la instalación y el servicio. Corrija todas las fugas de inmediato. ADVERTENCIA: Nunca use una llama abierta para revisar en busca de fugas. Aplique una mezcla de jabón líquido y agua en todas las juntas.
  • Página 54 INSTALACIÓN ANTES DE INSTALAR EL APARATO - Cierre el suministro de gas a la chimenea o a la caja de fuego. - Limpie el piso de la chimenea y la chimenea antes de instalar el conjunto de leños. Selle cualquier ceniza.
  • Página 55 ENSAMBLAJE DE LOS LEÑOS VFL2-SO18DT / VFL2-EO18DT / VFL2-SO24DT / VFL2-EO24DT ADVERTENCIA: No colocar las piezas de acuerdo con estos diagramas o no usar solamente piezas específicamente aprobadas con este calefactor puede resultar en daños a la propiadad o lesiones personales.
  • Página 56 ASSEMBLING LOGS VFL2-WW18DT / VFL2-RW18DT / VFL2-WW24DT / VFL2-RW24DT WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury. CAUTION: After installation and peridically thereafter, check to ensure that no yellow flame comes in contact with any log.
  • Página 57 OPERACIÓN PARA SU SEGURIDAD LEA ANTES DEL ENCENDIDO ADVERTENCIA: Si no sigue estas instrucciones exactamente, puede resultar un incendio o explosión ocasionando daños a la propiedad, lesiones personales o la muerte. A. Este aparato tiene una piloto que debe ser encendido por el encendedor electrónico. Cuando encienda el piloto, siga estas instrucciones exactamente.
  • Página 58 OPERACIÓN INSTRUCCIONES DE ENCENDIDO 1. ¡ALTO! Lea la información de seguridad que se indicó anteriormente. 2. Gire la perilla de control hacia la derecha a la posición “OFF” (Ver Fig. 25). 3. Espere cinco (5) minutos para que se vacíe todo el gas. Luego huela en busca de gas, incluyendo cerca del piso.
  • Página 59 OPERACIÓN INSPECCIÓN DE LOS QUEMADORES Revise con frecuencia el patrón de la llama del piloto y los patrones de la llama del quemador. PATRÓN DE LA LLAMA DEL PILOTO La Figura 27 muestra un patrón correcto de la llama del piloto. La Figura 28 muestra un patrón incorrecto de la llama del piloto.
  • Página 60 CUIDADO Y MANTENIMIENTO PATRÓN DE LA LLAMA DEL QUEMADOR La Figura 29 muestra un patrón correcto de la llama del quemador. La Figura 30 muestra un patrón incorrecto de la llama del quemador. El patrón incorrecto de la llama del quemador muestra puntas de llama esporádicas e irregulares.
  • Página 61 CUIDADO Y MANTENIMIENTO 1. Apague la unidad incluyendo el piloto. Deje que la unidad se enfríe durante 30 minutos. 2. Inspeccione el quemador, el piloto y los agujeros de entrada de aire primario en el porta orificio en busca de polvo y suciedad (Ver Fig.
  • Página 62 RESOLUCIÓN DE FALLAS ADVERTENCIA: Si huele gas: • Apague el suministro de gas. • No trate de encender ningún aparato. • No toque ningún interruptor eléctrico; no use ningún teléfono en su edificio. • LLame de inmediato a su proveedor de gas del teléfono de un vecino. Siga las instrucciones del proveedor de gas. •...
  • Página 63 RESOLUCIÓN DE FALLAS PROBLEMA CAUSA POSIBLE ACCIÓN CORRECTIVA 1. La perilla de control no está El ODS/piloto enciende 1. Oprima por completo la perilla de control. completamente presionada. pero la llama se apaga 2. La perilla de control no está 2.
  • Página 64 RESOLUCIÓN DE FALLAS PROBLEMA CAUSA POSIBLE ACCIÓN CORRECTIVA Residuo de polvo blanco 1. Cuando se calientan, los vapores 1. Apague el calefactor cuando use pulidor de que se forma dentro de del pulidor de muebles, cera, mueble, cera, limpiador de alfombra o productos la caja del quemador o limpiadores de alfombra, ect.
  • Página 65 Para piezas de repuesto, llame a nuestro departamento de servicio técnico al 1-877-447-4768, de lunes a viernes, de 8:30 a.m. a 4:30 p.m., hora estándar del Centro. VFL2-SO18DT/ VFL2-EO18DT/ VFL2-SO24DT/ VFL2-EO24DT VFL2-WW18DT/ VFL2-RW18DT VFL2-WW24DT/ VFL2-RW24DT NÚMERO DE PIEZA NÚM. DE DESCRIPCIÓN CANT.
  • Página 66 Garantía GARANTÍA LIMITADA: Esta garantía limitada se extiende al comprador original al por menor de este conjunto de calentador y garantiza contra cualquier defecto en materiales y mano de obra durante un periodo de (2) años a par tir de la fecha de venta al por menor. GHP Group, Inc., a su opción, proporcionará piezas de reemplazo o reparará...
  • Página 67 GARANTÍA LIMITADA REGISTRO DE LA GARANTÍA IMPORTANTE: Le urgimos que llene su tarjeta de registro de la garantía en el plazo de catorce (14) después de la fecha de compra También puede registrar su garantíaen internet en www.ghpgroupinc.com. Complete el número de serie. Conserve esta porción de la tarjeta para sus registros.