7. TROUBLESHOOTING
Symptom
Tool does not operate properly:
LED light flashing 5 times
LED light flashing 2 times
LED light flashing 3 times
Tool operates properly, but
fasteners do not drive fully
Tool operates properly, but
fasteners are driven too deep
Frequent empty stapling
Tool jams frequently
20V 18Ga Cordless Narrow Crown Stapler
Possible Causes
No staples
Battery is low
Tool is hot
Depth of drive isn't deep enough
Staple is too long for wood
hardness
Depth of drive is too deep
Jammed staples or damaged
staples
Incorrect staples
Damaged staples
Dirty magazine
Possible Solution
Replenish staples
Charge the battery pack
Wait until the tool cools down
Adjust depth of drive
Use staple length that is appropriate
for wood
Adjust depth of drive
Pull up on the tool free jam release
and unhook the latch. Check whether
there are jammed staples or damaged
staples inside. If so, remove the
jammed staples or damaged staples
in time.
Verify that staples are the correct size
Replace staples
Clean magazine
13
EN