ALLERTON™
HET TOILETS WITH 3"FLUSH VALVES
DIRECTIONS FOR TANK TO BOWL ASSEMBLY
This water closet has been designed for easy installation. Conventional
fittings have been used throughout so that the working parts and operation
of this assembly may be easily understood.
1. Before assembling tank (B) to bowl (K) check tightness of lock nuts on both flush valve and fill valve.
2. Assemble tank bolts (D) in tank with rubber washers (E) and plastic wing nuts (F). Wing nuts should
be tightened by hand sufficiently to compress rubber washers and insure water seal.
3. Assemble bevel washer (G) to flush valve shank so that lock nut is enclosed in recess, making sure
that the entire surface of the washer is in contact with the tank bottom.
4. Place two channel pads (H) in recesses on back of bowl ledge to prevent china-to-china contact.
5. Place tank assembly in position. All parts are supplied. USE NO PUTTY. Plastic wing nuts (F) are
tightened by hand sufficiently to prevent rocking; and since the tank bolts are already sealed, the
tank can be leveled by the relative amount that each wing nut is pulled down on the three points of
contact...bevel washer (G) and two channel pads (H).
6. Plastic bolt caps and washers (J) are provided to be used as indicated in the illustration.
7. The fill valve coupling nut (l) is provided to connect the water supply line to the fill valve. USE NO
PlPE DOPE!HAND TIGHTEN ONLY! OVERTIGHTENING MAY SPLIT THE FILL VALVE AND WILL
VOID THE WARRANTY!
8. Make sure refill tube adaptor is attached to the top of the flush valve overflow tube. Note: Flow from
the refill tube must be positioned directly over the overflow tube.
9. IMPORTANT: Always clear sand and rust from system.
• Remove valve top by lifting arm and rotating top 1/8 turn counterclockwise.
• While holding a container over the uncapped valve to prevent splashing, turn water supply on
and off a few times. Leave water supply off.
• Replace TOP by engaging lugs and rotating 1/8 turn clockwise. MAKE CERTAIN TOP IS
TURNED TO THE LOCKED POSITION. VALVE MAY NOT TURN ON IF TOP IS NOT FULLY
TURNED TO THE LOCKED POSITION.
10. Adjust water level in tank to marked water line. Turn the water level adjustment screw (L) to move
the float cup (M) up or down.
11. Check action and nut tightness (left hand thread) of tank lever (C). Also, check looseness of flapper
chain (there should be slight slack in chain when at rest) and seal of flush valve flapper.
DO NOT USE IN-TANK DROP-IN TOILET BOWL CLEANERS CONTAINING
CHLORINE OR BLEACH. Use of in-tank drop-in cleaners containing chlorine or
bleach VOIDS FLUIDMASTER™ WARRANTY and WILL RESULT IN DAMAGE to tank
components and may cause flooding and property damage.
DO NOT EXPOSE PLASTIC TRIM PARTS TO STRONG OXIDIZING AGENTS, CHLORINE,
OR ACID LEVELS OF LOWER THAN 5.0 pH. SOME BOWL/TILE CLEANERS CONTAIN
SUCH AGENTS.
TANK TYPE BOWL CLEANERS CAN CAUSE TANK COMPONENT FAILURE AND
DAMAGE. OUR WARRANTY EXCLUDES SUCH FAILURES.
(1) #99-399"B/C Coupling Nut
I
Écrou de raccordement
B/C Tuerca de unión
F
(2) #99-287"Plastic Bolt Caps & Washer
J
Rondelle et chapeau de boulon en plastique
Casquete plástico para tornillo y arandela
K
(k) Bowl
Cuvette
Taza
NOTE: Parts with " are included in unit bag,99-660
REMAQUE: Les piéces portant un " sont incluses dans ie sac.
AVISO: Las partes con " están incluidas en la bolsa de la unidad.
METAL/COPPER
GALVANIZED
METAL FLANGED
TUBING
PIPE (SEE NO TE)
TUBING
LOCK NUT
LOCK NUT
EXISTING
O-RNG
WASHER
CONE
WASHER
EXISTING
COUPLING
COUPLING
COUPLING
CAUTION:
NUT
NUT
NUT
DO NOT
USE
WATER
CONE
SHUT-OFF
WATER
WATER
SHUT-OFF
WASHER
SHUT-OFF
OR
O-RING
These parts must be used as illustrated to insure
Use existing
water-tight connection. Use of existing a coupling
coupling nut
WITH
nut may result in water leakage. Water supply tube
and washer.
PLASTIC
or pipe must extend at least 1/2'' inside threaded
SUPPLY
shank of valve(does not apply to flanged tubing).
LINE.
Flapper Assembly Replaced by 99-788
Float Cup
Coupelle flottante
L'etancheite Du Clapet
Flotador
Asamblea De Flotador
ALLERTON™ is a trademark of GERBER PLUMBING FIXTURES LLC.
FLUIDMASTER™ is the registered trademark of Fluidmaster lnc.
PN 8082, rev. 01-12
(A) Tank Cover
A
Couvercledu réservoir
Tapa del tanque
(B) Tank
B
Réservoir Tanque
(C) Tank Lever
C
Levier du réservoir
Palanca del tanque
(2) #99-596" Tank Bolt
D
Boulon de réservoír
Tornillo de tanque
E
(2) #99-580" Rubber Washer
Rondelle en caoutchouc
Arandela de goma
(4) #99-577" Plastic Wing Nut
F
Écrou papillon en plastique
Tuercas de orejas plásticas
G
(1) Bevel Washer
Rondelle oblique
Arandela cónica
H
(2) #99-579"Channel Pads
Coussinet de canal
Tacos acanalados
METAL SPIRAL
CAUTION: Overtightening of
TUBING
LOCK NUT or COUPLING NUT
could result in breakage and
LOCK NUT
LOCK NUT
potentiial flooding.
EXISTING
CONE
WASHER
COUPLING
NUT
FOR GALVANIZED
PIPE ONLY. you
must break out
WATER
SHUT-OFF
the center of
COUPLING NUT
Use existing spiral cone
by striking it lightly with ahammer
washer. Fluidmaster cone
or blunt end of screw driver handle.
washer may not seal
Discard center portion. Also,use
completely on spiral type
O-RING instead of cone washer.
supply line.
Water Level
L
Adjusting Screw
La vis de réglage de
niveau d'eau
M
El tornillo de reglaje del
nivel de agua
Replaced by 99-300