ENGLISH
moving the appliance from one place to another, always do it with the device in an upright
position and leaving it in a flat surface.
-
The air outlet pipe should be 28-150 cm long, this length is based on the specifications of
the air conditioner. Do not use extendible pipes or replace the pipe with a different one, as
this may cause the product to malfunction. The exhaust pipe must be clear of obstructions;
otherwise it may cause overheating.
Installing of the air outlet pipe. Fig. 7
1.
Stretch the air outlet pipe.
2.
Insert the pipe into the air outlet.
3.
Turn the end counterclockwise to fix it to the air conditioner body.
NOTE:
-
The flat end of the exhaust pipe joints must be snapped into place.
-
The air outlet pipe must not be twisted or bent more than 45°. Keep the air outlet pipe free
of obstructions.
Installing the window sealing plate
You can install the window sealing plate either vertically (Fig. 8) or horizontally (Fig. 9). Adjust
the size of the opening so that the sealing plate remains fixed in it.
The following checks must be applied to installations using flammable refrigerants:
-
The load size is in accordance with the size of the room where refrigerant-containing parts
are installed.
-
Ventilation machinery and outlets can be properly operated and are unobstructed.
-
If an indirect cooling circuit is used, the secondary circuit must be checked for refrigerant
presence.
Equipment marking remains visible and legible. Illegible markings and symbols should be
-
corrected.
-
The components or refrigerant piping are installed in a position where they are not
susceptible to exposure to any substance that may corrode the refrigerant-containing
components, unless the components are made of materials that are inherently resistant
to corrosion or are properly protected against it.
4. OPERATION
The following functions can be activated from the control panel or from the remote control.
On/Off
(Remote control)
When the device is turned on, it will beep and enter standby mode. Touch the power key to turn
64
FORCECLIMA 12600 SOUNDLESS HEATING
the device on and off.
Mode
(Remote control)
Press the mode icon to switch between cooling, fan, and dehumidification modes.
Note:
when the appliance is running in cooling and dehumidification mode, the condensate
drainage will be done through the upper condensate outlet. When the device is running in
heating mode, the condensate drainage will be done through the lower condensate outlet.
Note:
when changing from heating mode and vice versa, the appliance will take some time
to change from one mode to the other. It may take a few minutes for the appliance to start
running normally again.
Sleep mode
In cooling mode, press the increase and decrease icons to activate the Sleep mode. The device
will operate saving energy and silently.
Increase and decrease icons
Use these icons to increase or decrease temperature and time.
Temperature cannot be increased or decreased in fan or dehumidification mode.
Fan speed
Under the cooling mode, press the key to select high or low wind speed operation.
This option is not available under the dehumidification mode.
NOTE:
Under certain conditions (defrost), it may not operate at the selected speed.
Timer
Press this key to set the timer. When the timer symbol blinks, use the increase and decrease
icons to select the desired operating time.
The timer can be set from 1 to 24 hours, and the digits increase and decrease by 1 hour.
Unit switch: (Remote control)
Press the button to switch between ºC and ºF.
Oscillation
Press this button to activate the air oscillation.
Drainage instructions
When the air conditioner stops operating because the water tank is full, turn it off and unplug
it from the power supply. The full-tank indicator (FL) will start blinking on the display and the
ENGLISH
FORCECLIMA 12600 SOUNDLESS HEATING