ENGLISH
Water tank cleaning
-
To clean the water tank, fill it with clean water, shake it, and empty it.
-
The mop is washable; therefore, it is suggested to wash it after every use.
-
Replace the cloth after 20-30 uses, depending on the use.
-
When the mop cloth is used for a long time, it is possible that the water output is affected.
This can be avoided by cleaning both the mop and water tank regularly.
How to remove the battery
Press the battery release button and remove the battery as shown in figure 13. Store the
battery in a plastic bag and leave it in a dry place.
Device storage
Remove the battery and store it in a safe, dry place if the device is not going to be used in a
long period of time.
Maintenance indicator
If maintenance has not been carried out frequently enough, the appliance will display a full
tank or clogged filter icon on the screen. Fig. 14-15
7. TROUBLESHOOTING
Problem
Possible cause
The motor does not operate
The battery does not work
any longer.
The metallic tubes, floor
brushes, batteries or the
device itself are not properly
assembled.
The suction power has been
The dust tank is full. Fig. 14
reduced and the appliance
The filter has too much dust.
makes a lot of noise.
Fig. 15
The electric rotary brush inlet
is obstructed or the brush is
blocked. Fig. 16
Insufficient operating time
Insufficient charge time.
after charging the device.
The battery is old.
(The battery life may vary
according to the room
temperature).
48
Solution
Charge the vacuum cleaner.
Make sure all parts of
the device are correctly
assembled.
Clean the dirt.
Clean or replace the filter.
Clean the dust inside the
electric rotary brush.
Fully charge the battery
following the instructions in
this manual.
Batteries are easily
recycled. Go to the closest
maintenance point and buy
new batteries.
8. ERROR CODES
Code
Problem
E1
The device turns off and does not
charge.
E2
The device does not charge.
E2
The device does not charge.
The device turns off.
E3
The device turns off and displays E3.
E5
The device turns off and displays E5.
E6
The device turns off and displays E6,.
E9
The device turns off and displays E9.
E7
The device stops working or does not
turn on and shows E7.
E8
The device turns off and displays E8.
High-
The device stops or does not switch
efficiency
on. Fig. 15
filter
indicator
blinks
The filter set
It works normally. Fig. 14
logo flashes.
The brush
The long brush and motor stop
icon flashes
working. Fig. 16
9. TECHNICAL SPECIFICATIONS
Product reference: 05769
Product: Rockstar 1700 X-Treme ErgoWet
Voltage and frequency: 100-240 V ~ 50/60 Hz
29.6 V DC 2500 mAh 74 Wh battery
Motor rated power: 630 W
Brush rated power: 50 W
ENGLISH
Cause
Short circuit
The charger's voltage is below 36.3 V
The charger's voltage is below 32.1 V
Low battery
The motor short-circuits when the
battery is low
Main motor overload (second level)
Main motor overload
Temperature too high or low
Battery fault (first level)
NTC error (thermistor short circuit)
High-efficiency filter not installed
The dust tank or the inlet filter is
blocked
Blocked long brush
Long brush full of hair
CONGA ROCKSTAR 1700 X-TREME ERGOWET