EN I PATONA Platinum Powerstation Autarc 5000
4. To do this, press the overload circuit breaker and turn the system back on.
11 Handle fuses
► Press the handle fuse to retract/extend the handle.
Ports
Outputs
2x USB-A
2x USB-A
5V 2.4A
QC 3.0 18W
5x AC
1x KFZ
230V 2200W
12V 10A
Bypass function
► If the power station is connected to an AC power supply, devices connected to the power station can take power
directly from the AC power source without having to pass through the power station's battery first.
UPS function
► The UPS Uninterruptible Power Supply function automatically switches the connected devices that are currently
using the bypass function to the power station's battery within 10 milliseconds in the event of a power interruption to
the AC power supply. This ensures that the power supply is continuous.
Caution:
► For USA, JP: If the UPS icon flashes on the screen during the automatic switchover from the bypass function to
the UPS function, there is an overload, the power station will be shut down automatically. The maximum AC output
power is 1400W.
► For CN, UK, EU, KR: If the UPS icon flashes on the screen during automatic switching from bypass function to UPS
function, there is an overload, the power station will be shut down automatically. The maximum AC output power is
2000W.
2x USB-C
PD 100W
1x RV
2x Hohlstecker
24V 10A
12V 3A
15
Inputs
1x PV
120V 1000W
1x IEC
2x Hohlstecker
1800W
12V 3A