• Below the work surface
•
(Fig. D)
Step 1:
The hole in the work surface must be large
enough to allow the power cable with mains
plug
15
to pass through.
Insert the power cable with mains plug
the fitting thread
18
into the hole of the work
surface
Step 2:
Guide the cable guide ring white
below – with the closed surface facing down-
wards – onto the fitting thread
the power cable in the corresponding opening.
Step 3:
Screw the fixing nut
12
18
. Make sure that the housing is firmly
mounted on the work surface and tighten the
fastening nut again if necessary.
Step 4:
Fasten the enclosed flex. connecting hose
with the larger
/
" thread on the fitting thread
1
2
18
, and on the other side (
cold water valve.
Step 5:
After successful installation, open the water
supply. Note: Do not plug the mains plug into
the socket yet!
•
• Above the work surface
(Fig. E)
Step 1:
Guide the cable guide ring chrome
below – with the closed surface facing down-
wards – onto the fitting thread
the power cable in the corresponding opening.
Step 2:
Insert the fitting thread
work surface
Step 3:
Screw the fixing nut
12
18
. Make sure that the housing is firmly
15
and
13a
from
18
and place
onto the fitting thread
14
/
" thread) on the
3
8
13b
from
18
and place
18
into the hole of the
onto the fitting thread
mounted on the work surface and tighten the
fastening nut again if necessary.
Step 4:
Fasten the enclosed flex. connecting hose
with the larger
/
" thread on the fitting thread
1
2
18
, and on the other side (
cold water valve.
Step 5:
After successful installation, open the water
supply. Note: Do not plug the mains plug into
the socket yet!
• • Operation
•
• Commissioning
It is essential that all connections are carefully
checked for leaks after commissioning.
Check the operation of the fitting. To do this,
turn the lever
10
forwards.
Do not plug the mains plug into the socket until
there is no leakage.
•
• Set the water temperature
The water supply is switched off when the lever
is at an
10
angle of approx. 45°C to the fitting
body,
16
symbol "0"
Cold water: Turn the lever
marking). The lower you turn the lever, the
greater the water flow (the flow rate)
Hot water: Turn the lever
marking). The further you turn the lever back-
wards, the greater the water flow (flow rate)
will be. Attention: as the water flow (flow rate)
increases, the water temperature in the hot
water range decreases.
The display
17
shows the current water
temperature. Note: Due to the measuring point
inside the fitting body
temperature deviations between the escaping
water and what is shown on the display
Note:
Electricity is only used for hot water genera-
tion!
Assembly / Operation
14
/
" thread) on the
3
8
10
forwards (blue
10
backwards (red
16
, there may be slight
17
.
GB/IE/NI
13