Descargar Imprimir esta página

Vaporesso ARMOUR MAX Manual Del Usuario página 3

Ocultar thumbs Ver también para ARMOUR MAX:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 7
ENGLISH
USER INSTRUCATIONS
1. Install the Tank
Install the tank to the battery by screwing the base of tank. Make sure they are firmly
connected.
2. Replace the Coil
- Unscrew the base from the tank;
- Pull out the used coil from the tank;
- Install a new coil to the tank;
- Reattach the thread base into place.
* Refer to the figure 1.
3. Fill E-liquid
- Press the top cap button.
- Fill e-liquid through the hole, then lock the top cap in place firmly after filling is finished.
- Please wait 5 minutes for the e-liquid to soak into the coil completely.
* Refer to the figure 2.
4. Remove the Tank Protective Cover
To remove the tank protective cover, the base of tank need to be screwed off, then the
tank protective cover can be removed easily.
* Refer to the figure 3.
5. Adjust the Airflow
To adjust the airflow volume, please rotate the air-inlet ring on the bottom of the tank.
6. Power On/Off the Device
Press the power button 5 times in 2s.
7. Power Adjustment
ARMOUR MAX&S Kit is using the powerful GTi coil platform, and the suggested power
need to be noticed before start vaping.
GTi MESH Coils
GTi 0.2Ω MESH
Suggested Power
60-75W
8. Start Vaping
Press the power button to enjoy extraordinary vaping experience.
9. Charge the Battery
After connecting the Type-C cable to the battery, the battery indicator and remaining
charging time will be showed on the screen.
10. Lock or unlock the device
① Easy Lock: Slide the power&lock button up to lock the power button, and slide down
to unlock. (Remind: When using the easy lock function, please ensure that there is
e-liquid in the atomizer; Also, try not to keep sliding the power button up and down for
too many times in a short time.)
② Device Lock: Simultaneously press the "UP" & "DOWN" button for 1 second to lock the
device, Simultaneously press these two buttons again to unlock.
11. Choose a Mode
Press the power&lock button 3 times continuously to enter the menu setting.
*F(t): F(t) MODE (DEFAULT)
F(t) MODE is by adjusting temperature, heating speed and time, F(t) mode releases
the flavors of e-liquid adequately, delivering the perfect balanced tasting experience
consistently from the first puff throughout.
*PUL: PULSE MODE
PULSE MODE is a mode to improve vaping experience through constant voltage
output, delivering optimal flavor production, throat hit, nicotine satisfaction, and perfect
temperature cloud continuously.
*ECO: ECO MODE
ECO MODE is a normal mode of output wattage, you can according to the coil
resistance to adjust the best wattage for your needs. The vaping time will last longer
than the F(t) and Pulse mode.
*TC-NI/SS/TI: Temperature Control Mode
In the Temperature control mode, press "UP" or "DOWN" button to adjust the
temperature. When the present temperature model has been adjusted to the
maximum or minimum value, pressing the button once again, the Fahrenheit and
Celsius unit will be switched automatically. Press "UP" and power button simultaneously
for 1 second, the start power can be adjusted from 5-80W. Press "DOWN" and power
button simultaneously for 1 second, the temperature control resistance lock (TCR LOCK)
can be switched on or off.
*Setting: SYSTEM SET
System setting includes Smart, TCR Lock, Themes, Brightness, Puffs, Default and
Version options.
GTi 0.4Ω MESH
50-60W
SMART ON/OFF:
when this function is on and a TANK is installed, the system will recommend the best
power automatically. Under the F(t), Pulse, ECO mode, press "DOWN" and power button
simultaneously, the smart function can be switch on or off. (PS: THE SMART FUNCTION
WORKS IN GTI COIL PLATFORM ONLY!)
TCR Lock ON/OFF: When this function is on, the resistance will be locked under
temperature control mode.
Puffs: the 5 days' puff counter can be checked in this interface, also the puff can be
cleared after confirm the reset option.
PROTECTIONS
1. Short circuit protection & Low resistance protection:
When the load resistance is less than 0.1 Ω, press the ignition key devise will enter the
short circuit protection and close the output, screen will display "SHORT ATOMIZER".
2. Low resistance protection:
When the load resistance is less than 0.1 Ω, press the ignition key devise will enter the
Low resistance protection and close the output, screen will display "LOW RESISTANCE".
3. No load protection:
When no load resistance is detected, press power button could trigger the no load
protection, the device will close the output, at the same time OLED display will show
"CHECK ATOMIZER".
4. High resistance protection:
When the load resistance is larger than 5Ω, press power button could trigger the high
resistance protection, the device will close the output, at the same time OLED display
will show " CHECK ATOMIZER ".
5. Low voltage protection:
When the voltage of the battery cell is lower than 3.3V, press power button could trigger
the low voltage protection, the device will close the output, at the same time OLED
display will show "BATTERY LOW".
6. PCBA(Printed Circuit Board Assembly):
When the temperature of PCBA sensor reaches 60-75 degrees, screen display "OVER
HEAT" and output is closed.
7. Over discharge protection:
During the charging, the battery voltage will rises to 4.1V+/-0.05V,the screen will display
"100%".
8. USB High Voltage Input Protection:
Switching in the charger, stop charging when the input voltage to USB port exceeds 6V
and is lower than 30V.
9. Over charge protection:
During the charging, the battery voltage will rises to 4.2V+/-0.3V,the screen will display
"100%".
10. Auto-shut off protection
When POWER button is held for 10±1 seconds, the device will close the output, at the
same time OLED display will show "OVER TIME".
CAUTIONS
1. Please turn off the device when it is not in use.
2. Do not leave the charging device unattended.
3. Do not drop, throw or abuse your device, which may cause damage.
4. Please use a standard USB output charger with proper charging current and voltage
range.
5. Keep away from the water or any flammable gas, liquid .
6. Keep away from corrosive chemicals.
7. Do not expose the device to direct sunlight, dust, moisture or mechanical shock.
8. Do not expose the device to extreme temperature. (Recommended temperature
range:
-10~45℃ /14~113 ℉ while using and -10~45℃ /14~113 ℉ while storing).
9. EEE Recycling: The product should not be treated as household waste, instead, it
should be handed over to the applicable collection point for the recycling of electrical
and electronic equipment.
10. Battery Recycling: The product battery should not be treated as household waste,
instead, it should be handed over to the applicable used battery collection point for
recycling.
11. Only have your device repaired by Vaporesso. Do not attempt to repair it by yourself
as damage or personal injury may occur;
12. Do Not use batteries with broken surface, overheating, leakage and strange odor;
13. Charge the battery indoors only;
14. Recycle batteries in accordance with local laws and regulations.
15. Please use high-rate discharge batteries(≥25A).

Publicidad

loading

Este manual también es adecuado para:

Armour s