By means of the „STOP" button (D) you can switch off all massage programmes at any time.
(Massage unit returns to park position). During this period (approx. 15 Sec.)
cannot be operated! To provide a comfortable exit from the wash unit for the clients, you
have to remove the footrest (B) and after that you have to switch off the massage function (D).
• The massage function switches off automatically after 16 minutes. It can be restarted immediately
using button „Prog." (C).
• The remote control sticks magnetically to the covering on the left or right
Important user information regarding the remote control:
The wash-basin remote control unit is designed exclusively for the use of clients with dry
hands. To guarantee correct operation of the electronic components, the remote control unit
must in no circumstances be allowed to come into contact with water, shampoo or other
fluids.
If it is operated with hands covered in foam, or with dirty hands, the remote control unit
will not operate correctly, there will be lasting damage to the electrical components, and the keys may
become permanently soiled.
The guarantee does not cover damage to the electronics as a result of the effects of wetness!
If, in exceptional circumstances, stylists need to operate the remote control themselves, it is essential that
the plastic cover be used.
3. Base
The installations and corner valves are located in the base behind the inspection cover.
Please Note:
>
We recommend to provide the supply lines with a central shut-off device.
>
If the system is operated without a suitable shut-off device, the angle valves must be closed at the
end of business hours.
a. Inspection cover
• To open, press the chrome-plated button and pull to release the magnetic connection.
WARNING: Always isolate the complete system and secure against unintended switch-
on before opening the inspection cover!
To close the flap, place it on the top cover from below and press it against the frame until the
magnetic connection snaps in again (flush with the side paneling). Press the operating button in again.
b. Care of the plastic surfaces
• Clean the plastic surface of the base with a damp cloth or a micro-fibre cloth, if necessary with
a mild household cleaning fluid.
• Under no circumstance use an abrasive cleaner!
• Please ensure that spots of various hair chemical agents (above all directly applied colouring
agents) do not fall on the plastic surfaces, as these cannot be removed.
4. Height adjustment:
Before the customer sits down, put the chair in the lowest position:
➢ Press foot switch
ATTENTION: before actuating the foot switch, make sure that no objects such as
supporting cushion, handbags, etc. are standing close to the shampoo stations or are leaning
against it!! This can lead to damage to the shampoo station and the objects!!
➢ Extend the legrest using the remote control.
Set your personal, ergonomically optimal working height:
➢ Press the right foot switch (+) until the ergonomically optimal working height is reached.
ATTENTION:
➢ After the end of the treatment, bring the chair back into the lowest position, only then fully
retract the leg rest!
➢ Risk of injury! Customer may only get up when the chair is in the lowest position!
(Fig. 5)
(Fig. 3)
(Fig. 8)
on the left (-)
GB
3
the footrest
(Fig. 5).