Manual de Instruções
N.º MNS00058.00
During cycleperforming
Display indications :
- If END_BY_TEMPERATURE : shows the Product temperature;
- If END_BY_ TIME : shows the total remaining time.
"start" button :
- pushing "start" performs stand-by status of the cycle;
o Standby is indicated by flashing "Stb".
o Compressor and fan stop
- pushing again "start" the cycle starts again from when it was suspended.
The parameter "Stb" is used as time limitation of "stand-by" status : if the stand-by status is longer than
"Stb", the cycle is restarted automatically from the beginning.
"ON/OFF" button :
- Pushing for 2 secs stops definitively the cycle and conservation phase starts:
o if CHILL cycle , conservation setpoint = 2°C
o if FREEZE cycle , conservation setpoint = -20°C
"new" button :
- pushing the "new" button, the last cycle selected by the user is displayed for 3 seconds.
- pushing again the "new" button, the air temperature is displayed for 3 seconds.
Parameter "dC" : dC=0 cycle timers are in minutes
dC=1 cycle timers are in seconds
End of cycle ALARM : "End" as display message. Manual reset.
If END_BY_TEMPERATURE : Product temperature range ; Piercing probe p/n NT*INF* : -50T90°C
Light button is enabled.
Aux button is enabled.
HACCP button is enabled.
Mute button is enabled.
Defrost button is not enabled.
Parameters editing is not enabled.
Piercing probe heater is not enabled.
MNS00058.00
TEC13/57
PRT