EN I PATONA Platinum Powerstation Autarc 1200
► Do not insert any objects into the ventilation slots.
► Ensure a distance of at least 30 cm from walls and objects.07 AC Taste
07 AC button
► Briefly press the AC button to switch the AC output ports on/off.
► Press the AC button AND the On/Off button for 3 seconds to change the frequency (50Hz/60Hz).
► Press the AC button 10 times in quick succession to change the AC output power (100-120VAC or 220-240VAC).
► The electrical load must not exceed 1200W.
Attention:
Voltage standards vary from country to country. Please check the compatibility of voltage and frequency before connec-
ting the power station.
08 XT60 input
► Charging the Powerstation via car charging cable or solar panel.
09 AC input
► You can charge the Powerstation via the AC input.
► Ensure that the mains voltage and frequency of the Powerstation match the mains voltage and frequency of the
mains connection.
► Full charge approx. 2 hours via the mains.
10 Overload protection switch
► The safety circuit is triggered if the voltage is unstable, e.g. due to a lightning strike or other reasons and/or if the
input voltage at the AC connection is too high. This protects the Powerstation.
► If the safety circuit has been triggered, proceed as follows:
1. Switch off the Powerstation and disconnect all cables from the connections.
2. Check the mains supply and all devices that are to be connected.
3. If you do not detect any anomalies, you can put the Powerstation back into operation.
4. To do this, press the overload protection switch and switch the Powerstation back on.
Connections
Outputs
USB-A*2
5V/2.4A
AC output*2
1200W
AC 220-240V 50Hz
or
AC 100-120V 60Hz
TYPE-C*3
TYPE-C*1
PD-20W
PD-100W
Cigarette
DC output*2
lighter*1
12V/3A
12V/10A
Inputs
100-240V 15A
XT60 input
12-48V max. 15A
13
AC input
500W