The insert Main Power Switch must be switched
ON in order for the Remote Control to function.
The Power button will put the insert in a standby
mode. This will turn off all functions at once but
will hold the settings in memory. By pressing the
button again the unit will turn on at the same settings.
Each time this button is pressed, the intensity of the
flame decreases. There are five brightness levels you
can cycle through including the
This button will turn the power to the heater and
blower on and off. As an important safety feature, the
heating element is designed with a delayed activation
sequence. Therefore, when the heater is turned ON it
will take several seconds for the unit to begin blowing
hot air. Subsequently, the fan blower will continue to
run for several seconds after the heater is switched OFF.
The rotary switch (TEMPERATURE) controls the
thermostat feature to help regulate your room's
temperature accordingly.
The motors used on the fan and the flame generator assembly are pre-lubricated for extended bearing life and
require no further lubrication. However, periodic cleaning/vacuuming of the fan/heater unit is recommended.
Make sure the unit is turned OFF and unplugged whenever you are cleaning the heater or fireplace.
WARNING: Make sure the power is turned off before proceeding. Any electrical repairs or
rewiring of this unit should be carried out by a licensed electrician in accordance with
national and local codes.
If repairing or replacing any electrical component or wiring, the original wire routing, color
coding and securing locations must be followed.
WARNING: Electrical outlet wiring must comply with local building codes and other applicable
regulations to reduce the risk of fire, electrical shock and injury to persons.
WARNING: Do not use this fireplace if any part of it has been under water. Immediately call a
qualified service technician to inspect the fireplace and replace any part of the electrical system.
Warning: Disconnect power before attempting any maintenance or cleaning to reduce the risk
of fire, electrical shock or personal injury.