an appropriate refrigerant detector prior to and during work, to ensure
the technician is aware of potentially toxic or flammable atmospheres.
Ensure that the leak detection equipment being used is suitable for
use with all applicable refrigerants, i.e., non-sparking, adequately
sealed, or intrinsically safe.
Ensure that the area is in the open or that it is adequately ventilated
before breaking into the system or conducting any hot work. A degree of
ventilation shall continue during the period that the work is carried out.
The ventilation should safely disperse any rel leased refrigerant and
preferably expel it externally into the atmosphere. Where electrical
components are being changed, they shall be fit for the purpose and to
the correct specification. At all times, the manufacturer's maintenance and
service guidelines shall be followed. If in doubt, consult the manufacturer's
technical department for assistance.
Detection of flammable refrigerants: Under no circumstances shall
potential sources of ignition be used in the searching for or detection
of refrigerant leaks. A halide torch (or any other detector using a
naked flame) shall not be used.
Details of Product
It uses quality, effective and hermetic compressor with wide rang of starting
voltage, suitable ambient temperature: not higher than 100°F/38°C,
reasonable matching of the showcase system guarantees its powerful
refrigerant ability and energy saving.
Goods stored can be displayed clearly through the door made from clear
glass.
The thermal insulation layer of the appliance made from hard polyurethane
makes it be light and good ability to keep the items inside cold.
Cabinets are powder-coated steel exterior and white HIPS interior.
- 7 -