INSTALLATION MANUAL Installation of the Indoor unit
Before starting installation, decide on the position of the
indoor and outdoor units, taking into account the minim-
um space required around the units
Install the indoor unit in the room to be air conditio-
ning, avoiding to install in corridors or communal
areas.
Install the indoor unit at a height of at least 2.5 m
from the ground.
To install, proceed as follows:
Installation of the mounting plate
1. By using a level, put the mounting plate in a perfect
square position vertically and horizontally.
2. Drill 32 mm deep holes in the wall to fix the
plate;
3. Insert the plastic anchors into the hole;
4. Fix the mounting plate by using the provided tapping
screws
5. Check that the mounting plate is correctly fixed;
Note : The shape of the mounting plate may be different
from the one above, but installation method is similar.
Drilling a hole in the wall for the piping
1. Decide where to drill the hole in the wall for the pip-
ing ( if necessary ) according to the position of the
mounting plate;
2. Install a flexible flange through the hole in the wall to
keep the area intact and clean.
The hole must slope downwards towards the exterior
Note : Keep the drain pipe down towards the direction
of the wall hole, otherwise leakage may occur.
Electrical connections Indoor unit
1. Lift the front panel.
2. Take off the cover as indicated in the picture ( by
removing a screw or by breaking the hooks).
3. For the electrical connections, see the circuit diagram
on the right part of the unit under the front panel.
4. Connect the cable wires to the screw terminals by
following the numbering, Use wire size suitable to
the electric power input (see name plate on the unit)
and according to all current national safety code
requirements.
5. The cable connecting the outdoor and indoor units
must be suitable for outdoor use.
6. The plug must be accessible also after the appliance
has been installed so that it can be pulled out if nece-
ssary.
7. An efficient earth connection must be ensured.
8. If the power cable is damaged, it must be replaced by
an authorized Service Centre.
Note:The cable wires has been connected to the main
PCB of indoor unit by manufacturer according to the
model without terminal block.
Indoors
17
Outdoors
5mm
Front panel
wiring diagram
Terminal block cover