Descargar Imprimir esta página

Solter PRACTICO 130 Manual De Instrucciones página 14

Publicidad

Idiomas disponibles

Idiomas disponibles

ELECTROMAGNETIC DISTURBANCES
Electromagnetic interferences produced by welding equipment may interfere in the operation of
equipment which is sensitive to this kind of interference (computers, robots etc). Ensure that all the
equipment in the welding area is resistant to electromagnetic radiation. In order to reduce radiation as
much as possible, work with welding wires as short as possible and placed in parallel on the floor if
possible. Work at a distance of 100 meters or more from equipment which is sensitive to disturbances.
Ensure that the machine equipment is correctly earthed. If there are still interference problems despite
having taken the above described precautionary measures, the operator must take extra measures such
as moving the welding machine, using filters or protected cables to ensure that interference with other
equipment does not occur.
Emission class A equipment: - Intended for use in industrial areas.
Emission class B equipment: - Meets emission requirements in residential and industrial areas.
RECYCLING
In compliance with European Directive 2002/96/EC on waste electric and electronic equipment, this
equipment must be deposited in your local recycling centre at the end of its useful life.
GENERAL DESCRIPTIONS
MEANING OF THE INDICATIONS ON THE SPECIFICATIONS PLATE
EN 60974
S/N ...
MMA
Uo
X
I1 max.
I1 eff.
I2
U2
U1
X ph
50/60 Hz
IP XX
TECHNICAL SPECIFICATIONS
Input voltage (U1)
Maximum input current (I1 max)
MMA-TIG Duty cycle (40ºC) 40%
MMA-TIG Duty cycle (40ºC) 100%
No-load voltage (U0)
Efficiency
Consumption in idle state
Max. absorbed power
Temperature protection class
IP protection class
EMC class
Weight (Kg)
SOLTER SOLDADURA S.L.
International Standard for welding equipment
Serial number
MMA welding
No-load welding voltage.
Duty Cycle %.
Max. instantaneous absorbed current.
Max. effective absorbed current
Welding current (A).
Test voltage for welding current (I2).
Supplying voltage.
Number of phases to be connected
Frequency.
IP protection class.
PRACTICO 150
230V (220~240) 50/60Hz
H (180º)
A (Industrial)
230V (220~240) 50/60Hz
30A
150A
80A
62V
83%
28W
7
IP21
2
PRACTICO 130
30A
130A
60A
62V
82%
28W
7
H (180º)
IP21
A (Industrial)
2
12

Publicidad

loading

Este manual también es adecuado para:

Practico 15010100