Descargar Imprimir esta página

Metcal BVX-250 Guia Del Usuario página 7

Sistema de extracción de humos de la serie

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 81
BVX-250 Series Fume Extraction System
User Guide
3.3.
The BVX-250 is designed with a color-coded LED status ring. The LED ring
changes colors depending on the mode the unit is in, or if there is an issue with
one of the filters.
BLUE:
GREEN:
AMBER FLASHING:
AMBER:
RED FLASHING:
RED:
The Main Filter should be replaced
See Section 7.4 for filter replacement procedures.
3.4.
The unit's exhaust can be directed by the attached rotating diverter, or by
connecting the unit to your building's ventilation system.
360-Degree Rotating Exhaust Diverter
The BVX-250 features a 360-degree rotating exhaust diverter. The filtered air
coming from the unit can be easily exhausted in any direction. Simply rotate the
exhaust diverter to aim the air as desired for maximum operator comfort.
The adjustable air diverter rotates 360 degrees for maximum operator comfort.
Color-coded LED Status Ring
Power is on, unit is in idle mode
Power is on, unit is operating normally, extracting fumes
The Pre-Filter is not installed properly
The Pre-Filter should be replaced
The Main Filter is not installed properly
Managing Unit Exhaust
LED STATUS RING