3. Safety / 4. Transport, packaging and storage
The three possible case designs fulfil the criteria of the EHEDG approvals and are
approved for the hygienic industry in accordance with the appropriate standard.
Compliance with conformity is only given for certified versions that are marked with the
EHEDG logo in the data sheet. EHEDG-compliant diaphragm seal systems are marked
as model DSSA11SA-E on the product label.
→ For further information, see data sheet DS 95.25.
4. Transport, packaging and storage
CAUTION!
Damage through improper transport
With improper transport, a high level of damage to property can occur.
When unloading packed goods upon delivery as well as during
internal transport, proceed carefully and observe the symbols on the
packaging.
With internal transport, observe the instructions in the following
chapters
4.1 Transport
Check the instrument for any damage that may have been caused by transport. Obvious
damage must be reported immediately.
4.2 Packaging
Do not remove packaging until just before mounting.
Keep the packaging as it will provide optimum protection during transport (e.g. change in
installation site, return).
4.3 Storage
Permissible conditions at the place of storage:
Storage temperature: -35 ... +70 °C [-31 ... +158 °F]
Avoid exposure to the following factors:
Proximity to hot objects, when permissible storage temperature is exceeded by
radiation.
Mechanical vibration, mechanical shock (putting it down hard), when the permissible
values are exceeded, see chapter 9 "Specifications".
Soot, vapour, dust and corrosive gases.
Hazardous environments, flammable atmospheres
Store the instrument in its original packaging in a location that fulfils the conditions listed