Restoring the factory settings
When the machine is on and OFF appears on the LED display, press the SEAL+SET button simultaneously
for 3 seconds. When the unit beeps and displays rS, this indicates that the reset to default settings has
been successfully completed.
3.4.
Cleaning and maintenance
a)
Always unplug the device before cleaning or putting it away.
b)
Use only non-corrosive cleaners to clean the surface.
c)
Use only mild, food-safe detergents to wash the device.
d)
After cleaning the device, all parts should be dried completely before using it again.
e)
Store the unit in a dry, cool place, free from moisture and direct exposure to sunlight.
f)
Do not spray the device with a water jet or submerge it in water.
g)
Do not allow water to get inside the device through vents in the housing of the device.
h)
Clean the vents with a brush and compressed air.
i)
The device must be regularly inspected to check its technical efficiency and spot any damage.
j)
Use a soft, damp cloth for cleaning.
k)
Do not use sharp and/or metal objects for cleaning (e.g. a wire brush or a metal spatula) because they
may damage the surface material of the appliance.
l)
Do not clean the device with an acidic substance, agents of medical purposes, thinners, fuel, oils or
other chemical substances because it may damage the device.
3.4.1.
Filling / draining oil from the pump
The pump should be filled with oil when:
1) When using the unit for the first time, oil must be poured into the pump. After the first 25 hours of
operation, the oil should be topped up again.
2) When the volume of oil in the pump is below the lowest level, it should be topped up.
3) The performance of the machine seriously deteriorates - check the oil level and top up if necessary.
4) After 60 hours of operation or after 6 months of use, the machine should be filled with oil.
Steps for filling with oil:
1) Use a screwdriver to open the rear cover.
2) Unscrew the cap.
3) Fill the pump with oil using an oil bottle until the oil level in the pump reaches 1/2~3/4.
4) Tighten the nut.
5) Reinstall the rear cover
1 - Oil filler cap; 2 – Oil pump; 3 - Oil level gauge
Steps for draining the oil:
1) Prepare a container and place it directly under the oil drain hole.
2) Using a spanner, unscrew the cap counterclockwise and the oil will begin to drain.
3) Once all the oil has drained, tighten the cap.