Down Position
P59
Adjustment
Testing Speed
P60
(rpm)
Testing A
P61
Testing B
P62
Testing C
P63
Running Time of
P64
Testing B and C
Stop Time of
P65
Testing B and C
Machine Protec-
P66
tion Switch Test
Trimming Protec-
P67
tion Switch Test
Factory Type
P70
Selection
Presser foot re-
P71
lease buffer duty
cycle (%)
needle position
P72
correction
Under needle
P73
position correc-
tion
Backstitch output
P76
of full time (ms)
Freedom sew
P77
back seam even
terminate pause
time (ms)
Thread Clamp
P78
release angle
0-1439
360
Down Position Adjustment
The needle will advance stop when the value
decreased
The needle will delay stop when the value in-
creased.
100-
2000
Setting testing speed.
3700
ON/
OFF
Option of Testing A, after setting press (1060.
OFF
TV) to set the speed keep running.
ON/
OFF
Option of Testing B, after setting press (060.
OFF
TV) to set the speed execute the cycle of Start -
Sewing -Stop - Trimming
ON/
OFF
Option of Testing C, after setting press (060.
OFF
TV) to set the speed execute the cycle of Start
Sewing.
Stop without positioning function
1-250
20
Setting running time of testing B and C
1-250
20
Setting stop time of testing B and C
0-2
1
0: Disabled:
1: Testing zero signal,
2: Testing positive signal
ON/
OFF
OFF: Disabled, ON: Enabled
OFF
20
0-50
2
Adjusts the presser foot release buffer duty
cycle.
0-1439
0
Manual hand rotation to the appropriate position.
0-1439
0
Manual hand rotation to the appropriate position.
10-990
250
20-200
75
10-150
100
The positioning angle of starting clamp
10