Connecting the
telephone line
Fig 2.2 - A common mode
choke must be used (2.2 mH)
for telephone line.
p. 14
Activating the SIM
card
The SL6+ can only recognize
the PIN code if the code is
set to "1234", "0000", "1111"
or if it is deactivated. If set to
anything else, the SL6+ can not
use the SIM card.
p. 15
Mounting
If GSM interface is installed it
has priority. If no active SIM
card is used, GSM interface
should be disabled.
p. 9
Fig 2.1 - Connect the telephone line in parallell in universal termi-
nals or the RJ-plug, see the picture above.
It's possible to connect up to nine SL6+ main units to the same
telephone line.
In order to access the unit remotely, it needs to be assigned a unit
number. Please refer to parameter *82* in the "Parameter List" for
more information.
Fig 2.2 - Note: a common mode choke is required (2.2 mH) if you
have an SafeLine SL6+ with a PCB version below 1.50. You can iden-
tify the PCB version on your SL6+ by checking the main board's
7-figure number, e.g. "0175146", where the last three numbers in-
dicates the PCB version. If you have an SL6+ with a version number
above this, you may disregard this information.
Setting the PIN code
1. Insert the SIM card in an ordinary cell phone. In the phone's
security settings, change the PIN to "1234". If not possible, set
the PIN code to "0000" or, if available, set the "PIN code request"
option to "OFF".
2. Verify the PIN code by switching your phone off and on again.
3. Make a call from your phone to verify that the SIM card is active
4. Make a call to the SL6+ after insertion to ensure there is a proper
connection.
If the PIN code is set to "1234", "0000"or deactivated, the SIM card can
be used on any of SafeLine's GSM products.
"1111" PIN code
If the PIN is set to "1111", the code will be randomly generated by the
SafeLine GSM unit and memorized. This is a safety measure, making
sure the SIM card will only work with the selected SafeLine GSM unit.
To change the PIN again, use the PUK code provided to you by your
mobile services provider for setting up a new PIN.
Install the main unit in the machine room. Mount the SL6 main unit
to a stable surface (eg. wall, controller cabinet), using appropriate
screws. No termination resistance is needed at the ends of the bus.
To avoid GSM interference: Place the main unit, the stations and
the GSM antenna at least 1,5 meters apart (Fig 5.1). The antenna
must be placed on a metallic (earthed) surface of at least 150x150
mm and be placed standing (vertical).
29