INSTRUGnON MANUAL
Industrial Triplex Pumps
INDUSTRIAL TRIPLEX PUMPS
TROUBLESHOOTING GUIDE
Symptom
Possible causa(s)
Corrective Action
Oil leak
between
Worn rod oil seals
Replace crankcase piston rod seals
crankcase
and pumping
section
Frequent or
Cracked, damaged
Replace plungers
premature failure or worn plunger
of
the packing)
Overpressure to
Reduce inlet pressure
inlet manifold
Material in the fluid
Install proper filtration on
being pumped
I
pump inlet plumbing
Excessive pressure
Check pressures and fluid inlet
and/or temperature of
temperature; be sure they are
fluid being pumped
within specified range
Running pump dry
Do not run pump without water
Pump runs
Pump is not primed
Flood suction then restart pump
but produces
no flow
Pump fails
Air is trapped inside pump
Disconnect discharge hose from pump.
to
prime
Flood suction hose, restart pump and run
I
pump until all air has been evacuated
Pump looses
Air leak in suction
Remove suction line and inspect
prime, chattering hose or inlet
it for a loose liner or debris lodged
noise, pressure
in hose. Avoid all unnecessary
fluctuates
bends.
Do
not kink hose
Clogged suction strainer
Clean strainer
Low pressure
Unloader valve is by-passing Make sure unloader is adjusted property
at nozzle
and by-pass seat is not leaking
Incorrect or worn nozzle
Make sure nozzle is matched to the
flow and pressure
of
the pump. If
the nozzle is worn, replace
Worn packing or valves
Replace packing or valves
Pressure gauge
Valves wom or blocked
Clean or replace valves
fluctuates
by foreign bodies
Packing worn
Replace packing
Low pressure
Worn nozzle
Replace with nozzle
of
proper size
Low engine RPM
Increase engine RPM to 3400
Air leak in inlet plumbing
Disassemble, reseal and reassemble
6- ENG