Use flexible hoses in order to prevent trans-
mitting unacceptable loads to the pipeline
system at the connection between the com-
pressor system and the pipeline system.
•
It is essential to use separators, traps and
drains which process the liquids produced by
the compressor before the compressor sys-
tem is put into operation.
•
Supply hoses at pressures above 7 bar
should be equipped with a safety cable (e.g.
a wire rope).
6. Assembly and starting
Notice!
You must fully assemble the appliance before
using it for the fi rst time.
6.1 Fitting the wheels (3)
Fit the supplied wheels as shown in Fig. 4.
6.2 Fitting the castors (4)
Fit the supplied castors (4) as shown in Fig. 5.
6.3 Fitting the transport handle (9)
Screw the transport handle (9) to the compressor
as shown in Figures 6 to 7.
6.4 Replacing the oil sealing plug (14)
Remove the transportation cover from the oil fi ller
opening with a screwdriver and insert the sup-
plied oil sealing plug (14) into the oil fi ller opening
(Fig. 8).
6.5 Fitting the quick-lock coupling for tank
pressure (13)
Screw the quick-lock coupling for unregulated
tank pressure (13) to the pressure vessel (2) as
shown in Figures 9 to 10.
6.6 Power supply
•
The motor is fitted with an overload switch
(Fig. 2/Item 16). If the compressor overloads,
the overload switch switches off the equip-
ment automatically to protect the compressor
from overheating. If the overload switch trig-
gers, switch off the compressor using the ON/
OFF switch (8) and wait until the compressor
cools down. Then press the overload switch
(16) and restart the compressor.
•
Long supply cables, extensions, cable reels
etc. cause a drop in voltage and can impede
motor start-up.
Anl_TE-AC_430-50-10_SPK13.indb 18
GB
•
In the case of low temperatures below +5°C,
motor start-up is jeopardized as a result of
stiffness.
6.7 On/Off switch (8)
To switch on the compressor, pull out the knob
(8).
To switch off the compressor, press the knob (8)
back in. (Figure 2)
6.8 Adjusting the pressure: (Fig. 1,2)
•
You can adjust the pressure on the pressure
gauge (6) using the pressure regulator (7).
•
The set pressure can be taken from the quick-
lock coupling (5).
6.9 Setting the pressure switch
The pressure switch is set at the factory.
Switch-on pressure 8 bar
Switch-off pressure 10 bar
7. Replacing the power cable
If the power cable for this equipment is damaged,
it must be replaced by the manufacturer or its
after-sales service or similarly trained personnel
to avoid danger.
8. Cleaning, maintenance and
ordering of spare parts
Warning!
Pull the power plug before doing any
cleaning and maintenance work on the ap-
pliance.
Warning!
Wait until the compressor has completely
cooled down. Risk of burns!
Warning!
Always depressurize the tank before carrying
out any cleaning and maintenance work.
Warning!
After use, always switch off the equipment
immediately and pull out the power plug.
8.1 Cleaning
•
Keep the safety devices free of dirt and dust
as far as possible. Wipe the equipment with a
clean cloth or blow it with compressed air at
low pressure.
•
We recommend that you clean the appliance
immediately after you use it.
- 18 -