WARNING !
!
AS SOON AS THE REASON FOR THE MACHINE STOPAGE IS ELIMINATED, UNLOAD THE LINEN
FROM THE DRUM IMMEDIATELY.
RISK OF FIRE!
4.6. HOW TO PROCEED ON ERROR MESSAGES
Version - Full Control : Error message occurs on the machine display in the form of Er: and no. of failure
(001 - 999). In some cases the programmer buzzer sounds. In some cases the drum goes on turning but
the heating is off. The machine cools down and stops itself after it has reached safety temperature. After
the machine has been stopped, the error message is possible to delete by opening and closing the door, possibly
by pressing the button of emergency stop. If failure state continues, the error message is displayed again.
For detailed information concerning error messages - see „Programming manual".
Version - Easy Control without coin meter and with coin meter : When there is an error the fault LED lights
on. The number on the display corresponds with specific fault. In some cases the drum goes on turning but
the heating is off. The machine cools down and stops itself after it has reached safety temperature.
For detailed information concerning error messages - see „Programming manual".
4.7. POWER SUPPLY INTERRUPTION
Version - Full Control : When the power supply interruption occurs and the power is restored the machine
will be in stand-by mode. The display is counting down. Once the display reaches 0 the machine will be waiting
for further instruction. Close the door in case it is open.
On the display the program number will be shown. Press the Start button to continue on the program, or press
the STOP button to end the drying cycle.
Version - Easy Control without coin meter and with coin meter : When the power supply interruption occurs
and the power is restored the machine will be in stand-by mode. The display is counting down. Once the display
reaches 0 the machine will be waiting for further instruction. Close the door in case it is open.
On the display the program number will be shown and the LED on START button is flashing. Press the Start
button to continue on the program.
WARNING !
!
UNLOAD THE LINEN FROM DRYING DRUM. RISK OF FIRE AT HIGH TEMPERATURE OF DRYING!
4.8. INTERRUPTION OF GAS SUPPLY
Version - Full Control : When gas supply is interrupted there is displayed the message „HEATING FAILURE"
or „NO HEAT" when the temperature is not reached. The drum goes on turning but with heating off. As soon as
it reaches the safety temperature it will stop. Error message is possible to delete - see chapter 4.6. When gas
supply is recovered, it is possible to start the machine again.
Version - Easy Control without coin meter and with coin meter : When gas supply is interrupted the display
will show the gas error messages number 22, 23 or 24. The drum goes on turning but with heating off.
As soon as the machine reaches safety temperature it will stop. For details on error messages revert to
„Programming manual".
WARNING !
!
UNLOAD THE LINEN FROM DRYING DRUM. RISK OF FIRE AT HIGH TEMPERATURE OF DRYING!
4.9. RESET OF GAS HEATING
After you start the machine, an electronic system of the machine will try three times the gas ignition. If the gas
ignition does not occur during this time, the control unit of ignition will come over to safety block and the valve will
not open until it is reset.
There is a message on the display :
Version - Full Control : „GAS IGNITION RESET/STOP". Check the gas supply. Check whether the manual
shut off valve of gas is open. When you press the button „START", an electronic system of ignition will reset
and the machine will repeat ignition sequence. Probably, it will be necessary to try several times to push out
an air from the gas pipeline. If an error message is still displayed, put the machine out of operation and contact
the manufacturer or your dealer. When you press the button „STOP", the machine will stop. On the display
there occurs an error message „ignition failure". The error message is possible to delete - see chapter 4.6.
Version - Easy Control without coin meter and with coin meter : „22". Check the gas supply. Check whether
the manual shut off valve of gas is open. Turn off and on the machine by emergency stop button - (valid for Easy
control without coin meter) or by main switch. The machine ignition unit will reset. Probably, it will be necessary
to try several times to push out an air from the gas pipeline. If the error message is still displayed put the machine
out of operation and contact the manufacturer or your dealer.
12
USER´S MANUAL
PUBLICATION DATE 08/05
508 992