Descargar Imprimir esta página

Samsara EM31 Guia De Instalacion página 3

Sensor ambiental

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

1
Make sure your Samsara Gateway is installed.
Make sure both the Gateway and Environmental
Monitor are activated. This can be completed on
the
Samsara Dashboard
App.
2b
ACC-EM-P1
For the Probe Temperature ("EXT"), ensure four inches
below the device is free of obstructions to allow for
cable connection.
Note: Probe is sold separately.
5
ACC-EM-P1
Probe Installation Only (if applicable):
Remove the rubber plug at the bottom of the device. Insert the connector with grips facing forwards. Fasten
the connector with the screws. An "EXT" external temperature reading will appear on the screen. Note that both
ambient temperature and probe temperature are being recorded and surfaced in the Samsara cloud.
samsara.com/support
or on the
Samsara Fleet
4" (10cm)
Phillips 0
© 2023 Samsara Inc.
2a
Choose a mounting location for the device within
100 feet of the Gateway.
The Ambient Temperature ("INT") sensing tab is on
the side of the device. Place the device in a location
with open airflow, away from doors to avoid large
temperature fluctuations. Ensure the rubber plug on
the bottom of the device remains inserted when not
using an accessory temperature probe.
3
Mount the device using the attached adhesive
strips onto a clean, flat surface. For added security,
use the two ½" self-drilling screws included in the
packaging.
100' (30.5m)
3

Publicidad

loading

Este manual también es adecuado para:

Acc-em-p1