LAMp REpLAcEMENT
The UV-C lamps can be replaced by
removing the top plate.
If necessary, remove a filter housing to get
some more access to the UV-C lamps.
CAUTION -
ALWAYS UNPLUG THE MACHINE TO
AVOID DIRECT CONTACT WITH UV-C
LIGHT BEFORE OPENING THE FILTER
HOUSING!
8
MEDI 10
cAuTIoN
If the HEPA13/Carbon filter is exposed to
water, this may shorted or end the filter's
lifespan.
Filters cannot be cleaned and must be
replaced if they are saturated
Pre Filters must be replaced at least
every 2000 hours. The HEPA 13/Carbon
filter must be replaced at least every 8000
hours.
UV-C lamps must be replaced every 8000
hours to ensure proper operation.
Switching the MEDI 10 on and off often
shortens the lifespan of the UV-C lamps.
ALWAYS SWITCH OFF THE MACHINE IF
REPLACING FILTERS / LAMPS !
MAX-VAC.COM