Before installing the device, read the instructions
carefully. The installer and the final user must
observe the laws and standards, and make sure
that they comply with relative local regulations. The
device is assembled in compliance with existing
community laws and the Manufacturer declines any
liability in case of damage caused by incorrect use
or use in conditions differing from those indicated
on the nameplate and in these instructions.
Symbols and danger indications as listed
below are present in this instruction
manual.
WARNING:
If these instructions are not observed, personal
injuries or death brought by electric shock may occur.
This symbol means that an action must be taken.
If these indications are not followed, damage or
failure of the device may occur.
Suggestions and tips recommended to facilitate
the work.
1. PRODUCT DESCRIPTION
The device is an automatic pump controller designed for
hydraulic systems.
2. APPLICATIONS
The device finds its application in typical water supply systems
and rainwater systems in residential, buildings, gardening,
agriculture, and industry.
PRO PRESS
Device for control and protection
INSTALLATION AND FUNCTIONING INSTRUCTIONS
3. TECHNICAL DATA
VOLTAGE
ACCEPTABLE VOLTAGE
FLUCTUATION
FREQUENCY
MAXIMUM CURRENT
MAXIMUM POWER
MAXIMUM RUNNING
PRESSURE
MAXIMUM RUNNING
TEMPERATURE
DEVICE
PROTECTION DEGREE
DIMENSIONS
fig 5
TECHNICAL DATA UP/PLUS VERSION
VOLTAGE THREE-PHASE
ACCEPTABLE VOLTAGE
FLUCTUATION
FREQUENCY
MAXIMUM CURRENT
MAXIMUM POWER
of the electric pump
230 Vac
+/- 10%
50-60 Hz
10 A
1,5 kW (2 HP)
12 bar (1,2 MPa)
65°C
1C
IP 65
Fig. 5
115/230 Vac
+/- 10%
50-60 Hz
10 A
0,75 Kw (1 HP) / 1,5 kW (2 HP)

Publicidad

loading

Resumen de contenidos para Pearl PRO PRESS

  • Página 1 PRO PRESS Device for control and protection of the electric pump INSTALLATION AND FUNCTIONING INSTRUCTIONS Before installing the device, read the instructions carefully. The installer and the final user must 3. TECHNICAL DATA observe the laws and standards, and make sure that they comply with relative local regulations.
  • Página 2 4. PUMPED LIQUIDS fig 2 The product is suitable for clean water, not aggressive and not explosive liquids, without solid parcels or fiber potentially able to affect the device mechanically or chemically. In the presence of aggressive liquids, the product may be provided, on request, with a flow valve in AISI 306 instead of the standard flow valve in brass.
  • Página 3 Power cables without plugs must be connected to a ANTI-JAMMING FUNCTION switch in compliance with the relative local regulations. The system must be equipped with a If, for any reason, the pump stays off for 24 consecutive hours, residual current device (RCD) with a trip current lower the device will carry out a startup of the pump motor for about than 30 mA.
  • Página 4 12. TROUBLESHOOTING Electrical shock – Risk of death or serious personal injuries. Turn off the power before starting to work on the device. Check that the power supply cannot be restored accidentally. PROBLEM CAUSES AND SOLUTIONS - Check the electrical wiring (fig.4). The pump fails to start - Check the pump.
  • Página 5 PRO PRESS Dispositivo de control y protección de la electrobomba INSTRUCCIONES DE INSTALACIÓN Y FUNCIONAMIENTO Lea atentamente las instrucciones antes de instalar el aparato. Tanto el instalador como el usuario final 3. FICHA TÉCNICA deben seguir las instrucciones cuidadosamente de acuerdo con los reglamentos, normas y leyes FUENTE DE ALIMENTACIÓN...
  • Página 6 4. LÍQUIDOS BOMBEADOS El producto está indicado para usar con aguas limpias, no fig 2 corrosivas y líquidos no explosivos que no contengan partículas sólidas o fibras que puedan dañar el producto mecánica o químicamente. En presencia de líquidos corrosivos, se puede suministrar bajo pedido con una válvula de flujo de acero inoxidable en lugar de la válvula de latón estándar.
  • Página 7 Los cables de alimentación desenchufados deben REINICIO AUTOMÁTICO conectarse a un interruptor de alimentación conectado a la red eléctrica de acuerdo con la normativa local En caso de falta de agua, el aparato realiza automáticamente sobre cableado. La instalación debe contar con un 10 intentos dobles de reinicio de unos 5 segundos cada uno dispositivo de corriente residual (RCD) con una durante las 24 horas siguientes al bloqueo para permitir,...
  • Página 8 12. PROBLEMAS DE FUNCIONAMIENTO Descarga eléctrica - Riesgo de muerte o de lesiones personales graves. Desconecte la alimentación eléctrica antes de empezar a trabajar en el aparato. Asegúrese de que la alimentación eléctrica no pueda restablecerse accidentalmente. PROBLEMA CAUSAS Y SOLUCIONES - Comprobar las conexiones eléctricas (Fig.