Before installing the device, read the instructions
carefully. The installer and the final user must
observe the laws and standards, and make sure
that they comply with relative local regulations. The
device is assembled in compliance with existing
community laws and the Manufacturer declines any
liability in case of damage caused by incorrect use
or use in conditions differing from those indicated
on the nameplate and in these instructions.
This is the safety alert symbol. When you
see this symbol on your pump control or in
this manual, look for one of the following
signal words and be alert to the potential
for personal injury:
• DANGER: warns about hazards that will cause
serious personal injury, death, or major property
damage if ignored.
• WARNING: warns about hazards that can cause
serious personal injury, death, or major property
damage if ignored.
• CAUTION: warns about hazards that will or can
cause minor personal injury or major property
damage if ignored.
• NOTICE: indicates special instructions which are
important but not related to hazards.
WARNING:
RISK OF ELECTRIC SHOCK - Disconnect
power before working on or around the device.
This equipment should be installed by technically
qualified personnel. Failure to install it in compliance
with national and local electrical codes may
result in electrical shock or hazard, unsatisfactory
performance, or equipment failure. Installation
information is available through pump manufacturers
and distributors. This equipment must not be used
by children or people with reduced physical, sensory,
or mental abilities, or lacking in experience and
expertise unless supervised or instructed. Children
may not use the equipment, nor may they play with
the equipment or in the immediate vicinity.
If the power cord is damaged, it must only be
replaced by qualified personnel.
TOTAL CONTROL
Device for control and protection
Installation and operating instructions
CAUTION
Keep the work area clean, well-lit, and uncluttered.
Keep safety labels clean and in good condition.
Wear safety glasses while installing or performing
maintenance on the device.
Do not run pump dry. Fill the pump with water before
starting or it will be damaged.
Make sure all ELECTRICAL POWER IS OFF before
connecting any electrical wires. Follow all device
wiring instructions provided in the "Wiring" section
of this manual.
1. FEATURES AND ADVANTAGES
Starts and stops the pump depending on the opening and
closing of the taps.
Stops the pump in case of a water shortage and protects it
against dry running.
Can be energized with either 115 Vac or 230 Vac.
Is equipped with automatic restart in case of failure and
system operational test during extended periods of inactivity.
Can be installed with surface or submersible pumps.
No need for an expansion tank, check valve, filter, or fittings.
Simple installation saves time and space.
Maintenance free.
2. TECHNICAL DATA
SINGLE-PHASE MAINS VOLTAGE
ACCEPTABLE VOLTAGE FLUCTUATION
FREQUENCY
MAXIMUM CURRENT
MAXIMUM POWER
DEVICE
MAXIMUM OPERATING PRESSURE
MAXIMUM OPERATING TEMPERATURE
FLUID TEMPERATURE
MINIMUM FLOW
MALE CONNECTORS
PROTECTION DEGREE
of the electric pump
115 Vac - 230 Vac
± 10%
50-60 Hz
20 A at 115 Vac/ 20 A at
230 Vac
1.1 kW (1.5 HP) at 115 Vac/
2.2 kW (3 HP) at 230 Vac
Type 1.B
174 psi (12 bar)
149°F (65°C)
77°F (25°C)
~ 0.26 GPM (1 l/min)
Mod. CPF: NPT 1 ¼"
Type 4

Publicidad

loading

Resumen de contenidos para Pearl TOTAL CONTROL

  • Página 1 TOTAL CONTROL Device for control and protection of the electric pump Installation and operating instructions Before installing the device, read the instructions carefully. The installer and the final user must observe the laws and standards, and make sure that they comply with relative local regulations. The...
  • Página 2 3. INSPECT YOUR SHIPMENT CAUTION: If you are not sure of the proper electrical connections, employ a competent electrician for the All pump controller devices are carefully tested, inspected, and installation. This ensures the installation complies with packaged to ensure their arrival in perfect condition. When the all noted electrical codes.
  • Página 3 Follow all the indications on the electrical diagrams (fig. 8, 9). Fig. 6 Fig. 8 Install the nuts with the arrow pointing towards the device as shown in the figures. Fig. 9 The components labeled with X in Fig. 5 and 6 are not used for the relative application.
  • Página 4 7. CONTROL PANEL - System pressure regulated at 65 psi (4.5 bar) The pump pressure must be a minimum of 87 psi (6 bar) and a GREEN LED ON Power on Device energized maximum of 174 psi (12 bar). The water column between the device and the highest tap must YELLOW LED ON Pump on Pump running...
  • Página 5 10. MAINTENANCE WARNING: Before disconnecting the pump, make sure The device is maintenance-free. In the case of system that the fuse box leads are disconnected, or the power maintenance, review and understand the following safety is turned off. After reassembling the pump, refer to the warnings and product instructions before performing any priming instructions before running..
  • Página 6 TOTAL CONTROL Dispositivo de control y protección de la electroboma INSTRUCCIONES DE INSTALACIÓN Y FUNCIONAMIENTO Lea atentamente las instrucciones antes de instalar el aparato. Tanto el instalador como el usuario final deben seguir las instrucciones cuidadosamente de PRECAUCIÓN acuerdo con los reglamentos, normas y leyes locales.
  • Página 7 3. INSPECCIÓN DE SU ENVÍO PRECAUCIÓN Si no está seguro de las conexiones eléctricas apropiadas, contrate a un electricista Examine el producto cuidadosamente para garantizar que no competente para la instalación. Esto asegura que la haya sufrido daños durante el envío. Cuando reciba el dispositivo, instalación cumpla con todos los códigos eléctricos examínelo detenidamente para asegurarse de que no se hayan anotados.
  • Página 8 Respete las indicaciones de los diagramas eléctricos (fig. 8, 9) Fig. 6 Fig. 8 Instale el conector del cable/conducto con la flecha apuntando Fig. 9 hacia el control de flujo, como se muestra en las figuras. Los componentes marcados con una X en las fig. 5 y 6 no se utilizan para esa instalación específica.
  • Página 9 7. PANEL DE CONTROL - Presión de la instalación regulada en 65 psi (4.5 bar) La presión mínima de la bomba debe ser de 87 psi (6 bar), y la LED VERDE ENCENDIDO Power on Aparato con tensión máxima de 174 psi (12 bar). La columna de agua entre el aparato y el grifo más alto no debe LED AMARILLO ENCENDIDO Pump on...
  • Página 10 10. MANTENIMIENTO ADVERTENCIA Antes de desconectar la bomba, El dispositivo no requiere mantenimiento. En caso de cerciórese de que los contactos de la caja de fusibles estén mantenimiento del sistema, revise y comprenda las siguientes desconectados o que se haya apagado la alimentación advertencias de seguridad e instrucciones del producto antes eléctrica.